Reader Tamper
If the reader is pulled away from the wall, the tamper plug remains attached to the wall and
a reader tamper condition is generated.
The voltage on the Tamper line is normally low. If reader tamper is detected, the voltage on
the Tamper line becomes high and the reader sounds 3 long beeps every 5 seconds for two
minutes, then stops.
To clear a reader tamper condition, reattach the reader to the wall.
Usage
LEDs
Red
Default
Sounder
•
The reader sounds 4 rapid beeps when it is powered up or restarted.
•
If specified, the reader beeps once when a token is presented.
Cable Lengths
PAC door controllers only
Cable Gauge
7/0.2 0.34mm² 22AWG
16/0.2 0.5mm² 20AWG
32/0.2 1.0mm² 18AWG
Green
Access permitted
Distance from Reader to Controller
PAC 2100 / 2200
750' / 250m
1500' / 500m
3000' / 1000m
11
English
Red / Green
Access denied
PAC 202 / 512
230' / 70m *
230' / 70m *
230' / 70m *