Allmatic T.CO.O Manual De Instrucciones página 10

Sistema radio para bandas de seguridad mecánicas y resistivas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5. Learning
5.1 Learning of the T.CO.O transmitters on the first relay of the R.CO.O receiver.
Check that the DIP 3 and 4 of the T.CO.O
1
transmitter and of the R.CO.O receiver are set
in the same way.
Press and keep pressed the key
2
present on the R.CO.O receiver.
Release the key on the R.CO.O
3
receiver.
Press and keep pressed the key
4
present on the T.CO.O transmitter.
5
Release the key of the transmitter
For the successive learning, repeat the operation from point 1.
5.2 Learning of the T.CO.O transmitter on the second relay of the R.CO.O receiver
Check that the DIP 3 and 4 of the T.CO.O
transmitter and of the R.CO.O receiver are set
1
in the same way.
Press and keep pressed the key
2
present on the R.CO.O receiver.
DO NOT release the key on the
3
R.CO.O receiver.
Release the key on the R.CO.O
4
receiver.
Press and keep pressed the key
5
present on the T.CO.O transmitter.
6
Release the key of the transmitter
NOTE: in case in which instead 4 BIP are reproduced, it means that the maximum number of transmitters for the selected channel has been
reached and that no new devices on the same relay can be memorized.
In case in which a device previously memorized is then associated to the other relay, it will be automatically removed from the previous relay.
For example, if a device memorized on the relay 1 is memorized on the relay 2 it will be automatically removed from the relay 1.
5.3 Summary of the acoustic signalling during the learning phase
6. Selection of the type of signal on output relay
Beside the two R.CO.O receiver relays a jumper for the selection of the type signal to give on output is present. This signal can be:
1.
A clean contact : open contact in case of alarm and close if the alarm is not present
2.
A contact type 8K2 : resistance of the contact = 0 or ∞ (Open loop) Ohm in case of alarm and 8K2 if the alarm is not present. The control unit
connected to the device must be able to handle this type of signal.
The selection of the type of signal is carried out in the following way:
MEC.
6-1620153 rev2
04/08/2014
Acoustic signalling during the learning phase
Number of BIP
2
Transmitter correctly memorized
4
Mistake : the maximum number of transmitter for
selected channel has been reached
1
Maximum time up for the memorization of the
transmitter (10 second)
8K2
Jumper Pos. 1
Jumper Pos. 2
The R.CO.O receiver
emits ONE bip
The R.CO.O receiver emits TWO bip.
The learning has had a successful conclusion.
The R.CO.O receiver
emits ONE bip
The R.CO.O receiver
emits TWO bip.
The R.CO.O receiver emits TWO bip.
The learning has had a successful conclusion
Meaning
Position 1 : clean contact functioning (Mec)
Position 2 : 8K2 functioning (8K2)
ITA
ENG
FRA
ESP
DEU
POR
10 / 32