Technical data for interfaces
CLASSIC, PREMIUM, SYSTEM
Relay output
Configuration of internal dip switch (only SYSTEM)
Open Loop or Closed Loop
Setpoint setting
Potentiometer or
interface
Max. voltages
Max. currents
Max. contact resistance
Type of contact
Insulation IEC/EN 60065
Power setting function
Temperature control function
Internal potentiometer
Interface
AC 250 V, DC 30 V
AC 3 A, DC 3 A
100 m Ohm at DC 6 V / 1 A
SPST - NO
AC 2000 V (50 - 60 Hz) 1 min
Setting level OFF...100 %;
1% steps
Setpoint value specification
50 °C...650 °C, 5 °C steps
Setpoint value OFF...100 % or
50 °C ...650 °C
Setpoint value OFF...100 % or
50 °C ...650 °C