Description and Installation Procedure
dimmable LED-Driver
LPVC11A1C
Art.-No.:
464112
2. Installation Instructions
The installation must be carried out in accordance with international and national standards by a qualified
electrician only .
The LPVC11A1C unit is intended for use with LED requiring a constant current of 350mADC only.
Careful attention must be paid to polarity when connecting the + / - terminals. Before switching on the
supply voltage all LED must be completely wired and connected!
The LPVC11A1C is short-circuit-proof.
When working on the LED system it must be separated from mains.
For RFI protection mains and secondary wires have to be installed free of
intersection.
PWM units mounted outside of luminaries are to be screwed tightly on a suitable surface by using their screw
holes and attention has to be paid to fastening primary and secondary lines securely by strain relief.
The tc temperature may not be exceeded for any kind of mounting. The unit does not contain any serviceable
components and must not be opened.
3. Important Information
Our LED Drivers are surge-voltage-stable with values above those prescribed by the respective
standards. As a protection against high voltage surges, as they occur e.g. when switching fluorescent
lamps and discharge lamps with an inductive ballast, motors (fans, etc.) and other inductive charges, the
load circuits for devices of this kind are to be clearly separated from each other.
The LED Driver cannot be regulated via a phase cut-on or cut-off dimmer!
4. Safety Functions
In case of a short circuit or overload the LED Driver will automatically cut off. It does not have a fuse of the
conventional kind. Thus the load circuit is not separated!
As soon as the defect has been repaired, the LED Driver will automatically cut back in.
5. Excess Temperature
In case of excess temperature through external heat sources or impermissible covers the built-in over
temperature control will reduce power. As soon as the LED Driver has cooled off, it will automatically cut
back in.
6. Heat Dissipation and Heat Transfer
Operation in excess ambient temperature or through external heating will reduce the service life. During the
installation process (particularly into luminaires), heat dissipation (heat transfer) is to be provided through
suitable measures. The ambient temperature and/or tc temperature may not be exceeded at any time. We
are not liable for damage resulting from improper use.
Voltage supply
220-240VAC
Order-No.:
Input voltage
Input current
Power factor
Output channel
Control input
Overload/Short-circuit
Protection class
Cable
Diameter of wires: 0,75 – 1,5mm² / AWG 22-14
(Terminals)
Temperature range
Dimensions
L x W x H
Approbations
Order-No. 464112
03/2011
© SLV Elektronik GmbH, Daimlerstr. 21-23, 52531 Übach-Palenberg,
Germany, Tel. +49 (0)2451 4833-0
Technical properties subject to modification
Control input
1-10V
PWM- output
0-100%
LPVC11A1C
464112
220-240VAC
max. 100mA
0,55
PWM signal
3-30V / 350mA const. / 1-11W
1-10V / 0,2mA
Short-circuit cutout
II
Bared wire end: 6 mm
-20°C - +50°C
167 x 38 x 30mm