6. Replace the blades when the width of the tooth is
less than 8 mm/0.32 in. (C).
C
To replace the blades
WARNING: Use protective gloves when you
hold the blades.
WARNING: To prevent unbalance and
vibrations in the product, clean the cutting
attachment when you replace the blades.
Note: The blades are interchangeable.
1. Remove the center screw (A), the washer (B) and
the support cup (C).
Note: The center screw has a left hand thread
1050 - 002 - 12.04.2019
A
B
C
2. Remove the 4 screws (D), the lower blade (E) and
the shim (F).
3. Remove the 4 screws (G) and the top blade (H).
4. Install the blades in opposite sequence. Tighten the
screws equally when you install the blades.
To adjust the clearance between the
blades
WARNING: Use protective gloves when you
hold the blades.
D
E
F
G
H
11