Troubleshooting; Error And Safety Codes - Shinco SDO-10D Manual Del Usuario

Ocultar thumbs Ver también para SDO-10D:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Troubleshooting

Problem
The appliance doesn't
start.
The appliance doesn't
dry the air as expected.
Loud sounds from the
appliance.
Ice appears on the spools - This is a normal process. The appliance has an

Error and safety codes

Code
Meaning
E2
Temperature sensor is defec-
tive
P1
Appliance is defrosting
FL
Water tank is full or not insert-
ed correctly
In case of service requests please write an email to: service@shinco.net
Solution
- Check if the power supply cord is inserted cor-
rectly.
- Environmental temperature is too high or too
low.
- The dehumidifier has reached the preset humid-
ity setting.
- The water tank is not inserted correctly.
- Time was too short.
- Make sure the appliance is free from obstacles.
- The humidity setting isn't set low enough.
- Check if all windows and other openings are
closed.
- The room temperature is too low (lower than
5 °C).
- There is an appliance which emits water vapour
- The appliance stands tilted and not upright.
- The floor is not flat.
- Filter is blocked. Clean filter.
automatic defrost.
Solution
Disconnect and connect the power
supply cord. If error still occurs, con-
tact us.
Code will disappear automatically
when the appliance has defrosted
Empty the water tank and insert it
correctly into the appliance
9
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Sdo-16d

Tabla de contenido