CARE AND MAINTENANCE

All maintenance should only be carried out by a qualified service technician.
Cleaning
Before cleaning or performing any maintenance, remove the battery pack. For safe and proper
operation, always keep the tool and its ventilation slots clean.
Always use only a soft, dry cloth to clean your right angle drill/driver wrench; never use
detergent or alcohol.
12. Chuck Removal
The chuck can be removed and replaced.
a. Lock the variable-speed trigger switch (E) by
placing the direction-of-rotation selector (D) in
the center-lock position.
b. Rotate the keyless chuck (A) to open the chuck
jaws.
c. Use a screwdriver to remove the chuck screw
by turning it in a clockwise direction.
d. Insert a 5/16-in. hex key (not included) into the
chuck of the right angle drill/driver and securely
tighten the chuck jaws around the hex key.
e. Tap the hex key sharply with a mallet in a
counterclockwise direction. This will loosen the
chuck for easy removal.
NOTICE: The chuck screw has left handed threads. Attach a new chuck to the spindle and
tighten the chuck screw.