Descargar Imprimir esta página

Electrical Connection - AEG Electrolux DL8560-M Manual Del Usuario

Ocultar thumbs Ver también para Electrolux DL8560-M:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
EN
CONNECTIONS
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the
hood to the chimney using either a fl exible or rigid
pipe ø 150 or 120mm, the choice of which is left
to the installer.
To install a ø 150 pipe
• To install the dumper 10
• Fix the pipe in position using suffi cient pipe
clamps (not supplied).
To install a ø 120 pipe
• To install a ø 120 mm air exhaust connection,
insert the reducer fl ange 9 on the dumper 10.
• Fix the pipe in position using suffi cient pipe
clamps (not supplied).
• Remove any activated charcoal fi lters.
RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 125 mm in any shelf that may be
posi-tioned over the hood.
• Insert the fl ange 9 on the hood body outlet.
• Connect the fl ange to the outlet on the shelf
over the hood using a fl exible or rigid pipe ø120
mm.
• Fix the pipe in position using suffi cient pipe
clamps (not supplied).
• Fix the directional grille 8 on the recirculation
air outlet using the 2 screws 12e (2,9 x 12,7)
provided.
• Ensure that the activated charcoal fi lters have
been inserted.
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm.
All manuals and user guides at all-guides.com

ELECTRICAL CONNECTION

ø 150
10
10
12e
ø 125
18
ø 120
9
8
9

Publicidad

loading

Este manual también es adecuado para:

Electrolux dl8590-m