7 Filter Capacity
7.1 Filter Capacity PURITY Quell ST
Carbonate Hardness
in °dH (°KH)
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
28
31
35
By-pass and capacity table for combi ovens and conventional ovens
Depending on machine type, select by-pass setting 10% to achieve optimally treated water for the
combi oven/conventional oven. We will be happy to make specific recommendations.
Carbonate Hardness
in °dH (°KH)
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
By-pass setting
PURITY 450
50%
50%
50%
50%
50%
50%
40%
40%
30%
30%
30%
30%
30%
30%
30%
30%
20%
20%
20%
20%
20%
20%
20%
20%
20%
By-pass setting
PURITY 450
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
Filter capacity in litres
PURITY 600
8250
14100
8250
14100
8250
14100
7071
12086
6188
10575
5500
9400
4217
7207
3833
6552
3077
5260
2841
4855
2638
4508
2462
4208
2308
3945
2172
3713
2052
3506
1944
3322
1650
2820
1571
2686
1500
2564
1435
2452
1375
2350
1320
2256
1179
2014
1065
1819
943
1611
Filter capacity in litres
PURITY 600
4991
8530
4991
8530
4991
8530
4278
7311
3743
6397
3327
5686
2995
5118
2722
4652
2496
4265
2304
3937
2139
3655
1996
3412
1872
3199
1762
3010
1664
2843
1576
2694
1497
2559
1426
2437
1361
2326
1302
2225
1248
2132
PURITY 1200
25800
25800
25800
22114
19350
17200
13187
11988
9624
8884
8249
7699
7218
6793
6416
6078
5160
4914
4691
4487
4300
4128
3686
3329
2949
EN
PURITY 1200
15607
15607
15607
13378
11706
10405
9364
8513
7804
7203
6689
6243
5853
5508
5202
4929
4682
4459
4257
4071
3902
31