Technical Description; Description; Technical Specifications; Duty Cycle And Overheating - Air Liquide WELDTEAM 2.5 Instrucciones De Seguridad, Empleo Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9
EN
1.0

TECHNICAL DESCRIPTION

1.1

DESCRIPTION

The system consists of a modern direct current generator for the
welding of metals, developed via application of the inverter. This
special technology allows for the construction of compact light
weight generators with high performance. l'ts adjust ability, effec-
tivity and energy consumption make it an excellent work tool suit-
able for coated electrode.
1.2

TECHNICAL SPECIFICATIONS

DATA PLATE 130 A
PRIMARY
Single phase supply
Frequency
Effective consumption
Maximum consumption
SECONDARY
Open circuit voltage
Welding current
Duty cycle 10%
Duty cycle 60%
Duty cycle100%
Protection class
Insulation class
Weight
Dimensions
European Standards
DATA PLATE VERSION 150 A
PRIMARY
Single phase supply
Frequency
Effective consumption
Maximum consumption
SECONDARY
Open circuit voltage
Welding current
Duty cycle 10%
Duty cycle 60%
Duty cycle100%
Protection class
Insulation class
Weight
Dimensions
European Standards
1.3

DUTY CYCLE AND OVERHEATING

Duty cycle is the percentage of 10 minutes at 40°C ambient tem-
perature that the unit can weld at its rated output without overheat-
ing. If the unit overheats, the output stops and the over
temperature light comes On. To correct the situation, wait fifteen
TECHNICAL DESCRIPTION
230 V
50 Hz / 60 Hz
10 A
30 A
69 V
10 A ÷ 130 A
130 A
60 A
45 A
IP 23
H
Kg 3,5
220 x 120 x 320
EN 60974.1 / EN 60974.10
230 V
50 Hz / 60 Hz
11 A
35 A
69 V
10 A ÷ 150 A
150 A
70 A
55 A
IP 23
H
Kg 3,8
220 x 120 x 320
EN 60974.1 / EN 60974.10
minutes for unit to cool. Reduce amperage, voltage or duty cycle
before starting to weld again (See page IV).
1.4

VOLT - AMPERE CURVES

Volt-ampere curves show the maximum voltage and amperage
output capabilities of the welding power source. Curves of other
settings fall under curves shown (See page V).
1.5

EMC CLASSIFICATION

This equipment is developed to satisfy severe limits of Class B in
accordance to CISPR prescriptions.
2.0

INSTALLATION

IMPORTANT: BEFORE CONNECTING, PREPARING OR US-
ING EQUIPMENT, READ SAFETY PRECAUTIONS.
2.1
CONNECTING THE POWER SOURCE TO THE MAINS
ELECTRICITY SUPPLY.
Serious damage to the equipment may result if the power source
is switched off during welding operations.
Check that the power socket is equipped with the fuse indicated in
the features label on the power source. All power source models
are designed to compensate power supply variations. For varia-
tions of +-10%, a welding current variation of +-0.2% is created.
WARNING: THIS EQUIPMENT DOES NOT COMPLY WITH IEC
61000-3-12. IF IT IS CONNECTED TO A PUBLIC LOW VOLT-
AGE SYSTEM, IT IS THE RESPONSIBILITY OF THE INSTALL-
ER O R USE R O F T HE E Q UI PM E NT T O ENS UR E, B Y
CONSULTATION WITH THE DISTRIBUTION NETWORK OP-
ERATOR IF NECESSARY, THAT THE EQUIPMENT MAY BE
CONNECTED.
THIS CLASS A EQUIPMENT IS NOT INTENDED FOR USE IN
RESIDENTIAL LOCATIONS WHERE THE ELECTRICAL POW-
ER IS PROVIDED BY THE PUBLIC LOW-VOLTAGE SUPPLY
SYSTEM. THERE MAY BE POTENTIAL DIFFICULTIES IN EN-
SURING ELECTROMAGNETIC COMPATIBILITY IN THOSE
LOCATIONS, DUE TO CONDUCTED AS WELL AS RADIATED
DISTURBANCES.
2.2
CONNECTING THE POWER SOURCE TO THE MO-
TOR-GENERATOR SET
This welder is designed to allow the use of Motor-generator set to
provide an adequate supply for welder during the welding opera-
tions.
Before connecting the welder to the Motor-generator set, make
sure that the following requirements are fulfilled:
1.
Output socket of the Motor-generator set allows to connect
the power supply plug of the welder.
2.
Output of the Motor-generator set produces alternating sinu-
soidal voltage with nominal RMS value 230 V.
3.
Motor-generator set is able to deliver the adequate supply
current / power required for welding operation.
2.3
CONNECTION AND PREPARATION OF EQUIPMENT
FOR STICK WELDING.
• TURN OFF WELDER BEFORE MAKING CONNECTIONS.
CONNECT ALL WELDING ACCESSORIES SECURELY TO
PREVENT POWER LOSS. CAREFULLY FOLLOW SAFETY
REGULATIONS DESCRIBED IN SAFETY RULES.
1.
Fit the selected electrode to the electrode clamp.
2.
Connect the earth lead connector to the negative (-) quick-
connection terminal (Ref. 6 - Picture 1 Page 4.) and the earth
clamp of the workpiece near the welding zone.
3.
Connect the electrode clamp connector to the positive (+)
quick-connection terminal (Ref. 5 - Picture 1 Page 4.) .
CAUTION: MAKE THE ABOVE CONNECTION FOR DIRECT
POLARITY WELDING; FOR INVERSE POLARITY, INVERT
THE CONNECTION: EARTH LEAD CONNECTOR TO THE
3 EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Weldteam 3.2

Tabla de contenido