INSTRUCTIONS
OVERVIEW
The Phantom Ballast Commercial DE is an ideal ballast choice for efficient growing. It was
created with state-of-the-art microprocessor technology to utilize the industry's double-
ended 1000W HPS lamps. It operates on a 120/208/240V, 50/60 Hz power supply.
This ballast (and all 40 Series Phantom Ballasts) includes a Control Port on the side panel
which allows connection to and data communication with the Autopilot PX1 Lighting
Controller via USB. Use with the PX1 is optional—the 40 series ballasts operate perfectly
with standard manual control when not connected to a PX1. The power cord for the 40
Series ballasts now includes a ferrite collar which suppresses radio frequency interference.
WARNINGS
• This ballast and the Control Port are compatible only with the Autopilot PX1 Lighting
Controller. Do not connect any other device to the Control Port. Any attempt to
connect it to an unrelated device or control it with an incompatible controller may
result in damage to the ballast and will void the warranty.
• Use this ballast in greenhouses or indoor applications only. Position it in an area
away from excessive heat or contact with liquids.
• This ballast does not rely on the luminaire enclosure for protection against accidental
contact with live parts.
• For remote operations, use this ballast with a maximum lamp cord of 15 feet.
• Disconnect the ballast from the power supply before performing any maintenance,
lamp changes, or other modifications.
• Contact the retailer or distributor for service if the ballast does not work after
confirming the power connection, output connection, and bulb operation.
• Opening the ballast will void the warranty.
• Lamps with built-in ignitors will not work with this ballast. Not for use with external
ignitors.
• Always disconnect ballast's power cord before moving the unit or changing lamps.
• This product may cause interference to radio equipment and should not be installed
near maritime safety communications equipment or other critical navigation or
communication equipment operating between 0.45-30 MHz.

INSTALLATION AND CONNECTION

For proper lamp break-in, we recommend that you run the ballast and bulb at 100%
power for at least 12 straight hours after initial startup. This will improve lamp life and
performance.
1.
Find a suitable location for the ballast with sufficient cooling and away from any heat
source.
2.
Install the lamp firmly into the lamp socket of the reflector and connect the Lock &
Seal lamp cord to the ballast.
3.
Remove the power cord from the box. Plug the power cord into the power source
(electrical outlet).
4.
Plug the power cord into the power source (electrical outlet).
5.
Once lamp has fired, set your desired dimming ratio. Please note that the ballast
dims or raises output gradually to protect the lamp, so you might not see an instant
increase upon changing your output percentage.
MOUNTING THE BALLAST ON THE WALL (FOR REMOTE OPERATION)
• Using the template on the left, mark the mounting screw positions on the wall.
Screws need to be 145mm apart to ensure the screw head can be inserted into the
hole on the back of the ballast. It is recommended that the screws be mounted in a
www.Hydrofarm.com
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Phantom phb4010Phdekts2

Tabla de contenido