Process B. Correctly Select Your Pump
Shallow Well Pump Capacities
For RTS5(1/2HP), RTS7(3/4HP), and RTS10 (1 HP)
25
20
15
10
5
0
0
5
Pumping Depth in Feet
IMPORTANT: SELECT CORRECT VOLTAGE
VOLTAGE SELECTION DIRECTIONS
Warning!
Disconnect pump from your
source before servicing or
handling pump.
Be sure that incoming power
supply is same as voltage
115 15
selector switch setting.
To change voltage settings
slide switch as shown
until desired voltage is
230
230
visible on switch.
Be sure switch is completely
engaged.
Replace capacitor housing cover
and secure cover with screws.
Do not overtighten screws.
22700A375
Disconnect pump from power source before changing the pump
voltage. To change the voltage, the selector switch is located
underneath the plastic cover on top of the motor. To access
the switch, remove the eight screws holding the plastic cover.
To change the voltage setting, slide the switch as shown until
desired voltage is visible on the switch. The voltage number that
appears is the voltage setting for the pump. Be sure the switch
is completely engaged. Replace the capacitor cover and secure
the cover with the eight screws.
Wire Selection Guide
NAME-
PUMP
HORSE-
POWER VOLTAGE
PLATE
MODEL
AMPS
RTS5
115
8.6
or
1/2
230
4.3
RC5
115
11.2
3/4
RTS7
230
5.6
RTS10
115
12.6
or
1
230
6.3
RC10
RTS5
RTS7
RTS10
10
15
20
115 15
230
230
MAX. WIRE LENGTH IN FEET
USING AWG SIZE
#14
#12
#10
118
189
296
475
756
1184
1857
100
160
250
400
630
1000
1545
84
135
211
339
540
845
1327
Deep Well Pump Capacities
For RC5(1/2HP) and RC10 (1 HP)
14
12
10
8
6
4
2
0
25
20
30
FUSE AND CIRCUIT BREAKER SIZE GUIDE
STANDARD LINE
PLUG FUSE*
HORSE-
POWER
115V
1/2
20
3/4 & 1
30
*For circuits not over 150 volts to ground.
WIRING YOUR PUMP
Disconnect pump from power before servicing or handling pump.
Remove the cover from the pressure switch. Connect the bare
copper ground to the ground screw in the pressure switch.
Connect the power supply to the terminals marked "Line" in the
diagram below.
GROUND
CONNECTIONS
PIPING
Plastic PVC pipe is shown in the illustrations, but galvanized
steel pipe may be used if desired. All piping must be clean and
free of all foreign matter to prevent clogging. ALL JOINTS AND
CONNECTIONS IN THE WELL ASSEMBLY MUST BE AIRTIGHT. Even
a pinhole leak will prevent the proper operation of the pump
#8
(this is the most common problem). Use thread compound on all
464
threaded joints unless specifi ed otherwise.
385
331
2
40
50
60
70
Pumping Depth in Feet
LOW PEAK - CART. TYPE
FUSETRON - CART. TYPE
FUSTAT - PLUG TYPE*
230V
230V
115V
10
12
6-1/4
15
20
10
MOTOR WIRES
LINE
LINE
INCOMING POWER
RC5
RC10
80
90 100
CIRCUIT BREAKER
230V
115V
20
15
30
15