CONNECTION TO ALTERNATIVE SOURCES OF HEATING
The heaters with heating pump enable the water for sanitary use to be heated by alternative sources of energy
(e.g. central heating, solar power, ...) by installing one or two heat exchangers.
Options for connecting the water heater to various sources of heating are shown in the drawings below.
Legend:
1. Water heater
2. Central heating hot-water system
3. Solar panel
4. Differential thermostat with sensors (T1, T2, T3, T4)
5. Bypass pump
6. Expansion tank
7. Non-return valve
8. Safety valve
Connection to solar panels
T
2
1
4
6
T
1
12
8
7 14
11 13
15
Connection to solar panels and central heating hot-water system
50
9
3
8
7
5
10
9
1
T
7
5
2
T
T
3
12
9. Air relief valve
10. Fill/drain valve
11. Reduction valve
12. Drain valve
13. Stop valve
14. Test unit
15. Funnel outlet to the drain
Connection to the central heating hot-water system
2
9
T
2
3
TV
4
4
6
1
12
8
7 14 11 13
15
4
9
7
T
5
3
12
13
11
14
7
8
12
15
8
7
5
10
1
T
1