8

Technical data

Technical data
MODEL: SURFOX TURBO
PART NUMBER: 54–D 045
INPUT AMPERAGE: 120V, 50/60 Hz
OUTPUT AMPERAGE: 12-30 V, AC
INPUT CURRENT: 4 Amps
OUTPUT CURRENT: MAX 20 Amps
12
9

Safety features

Safety features

A) Sparks on the tip/work piece

To avoid short circuits (arcing), the machine automatically
stops when the insert touches the work piece (metal to
metal contact).

B) Internal temperature

To protect the internal components of the machine, there
are temperature sensors inside the machine. If the operat-
ing temperature is too high, the machine will shut down and
restart by itself when the temperature reaches an
acceptable level. There is an internal fan inside the machine
to keep all the components cool.
WARNING!
The inside temperature can increase for
many reasons: high ambient temperature, lack of
proper air circulation around the machine, fluctuations
in amperage, electrical set-up in the shop, etc.