Keypad for access control system, white LED
key backlighting, 1 input configurable as exter-
nal lock-release push button CA, 1 N/O relay
output, to be finished with a front panel
1. Description
The entry of a pre-configured code allows activation of the "F1"
local relay output, to control the opening of a rolling shutter, for
example. The device also has a local input which can be used to
activate the F1 output.
Access code programming takes place with the help of SaveProg.
The device can be installed in a stand-alone configuration, with a
local 5V power supply.
2. Features
• Supply voltage: 5V DC from additional power supply unit on
terminals 5V+ and 5V-.
• Absorption: 250 mA at 5V.
• Operating temperature: -25°C / +55°C.
• IP54 degree of protection.
• IK08 (Pixel), IK10 (Pixel Heavy) degree of protection against
impact.
3. Connection
Terminals:
• Local 5V power supply,
• Output relay (F1)
• Input for door command (CA)
Connections:
1. USB: for configuration and updating
2. RJ45: not used.
4. Configuration
Connect the PC to the USB and follow the SaveProg instruction
documents for specific details.
It is possible:
• To add/delete access codes.
The maximum number is 2000.
The codes vary in length, up to a maximum of 8 digits.
• To change the relay activation time.
• Change the timeout associated with the keystroke.
• Change the brightness of the LEDs.
5. Operation
Output F1 is activated through the entry of a pre-configured code.
On standby all the LEDs are on with the brightness value set via
Saveprog.
The user code is entered by following the sequence
code +
(Key):
• with the
(Key) key you go into "Code Entry" mode: the key
LED will blink until the code entry procedure is completed;
• with each number entered all the LEDs flash once, except for
the LED corresponding to the pressed key (which stays on) to
let the user know which button he pressed;
6
• pressing the
entered; the
- if the code is correct, all the LEDs flash 3 times and output
F1 is activated.
- if the code is incorrect, 8 digits are exceeded, or you exit
due to time out, the LED of the
repeatedly 3 times. You exit "Code entry" mode;
• the
(Cancel) key is used to exit "Code entry" mode direct-
ly.
When enabled, the input CA directly activates output F1.
After each press, a configurable timeout starts within which you
need to press the next entry sequence key.
When the timeout expires the system exits entry mode, making
the
(Cancel) key blink.
6. Updating
The device is updated with Winboot via the USB connection.
To upgrade you need to disconnect the device from the auxiliary
power supply, connect the USB to the PC and start the update.
While waiting for the update and throughout the update the white
LED
(Key) key stays on. The wait period lasts 30 sec.
The instruction manual is downloadable from the site www.
vimar.com
INSTALLATION RULES.
Installation should be carried out observing current installation
regulations for electrical systems in the Country where the prod-
ucts are installed.
CONFORMITY.
EMC directive
Standards EN 60065, EN 61000-6-1 and EN 61000-6-3.
INFORMATION FOR USERS UNDER DIRECTIVE
2012/19/UE (WEEE)
In order to avoid damage to the environment and human
health as well as any administrative sanctions, any appli-
ance marked with this symbol must be disposed of separately
from municipal waste, that is it must be reconsigned to the dealer
upon purchase of a new one. Appliances marked with the crossed
out wheelie bin symbol must be collected in accordance with the
instructions issued by the local authorities responsible for waste
disposal.