General Notes

General Notes
V entilation line
G e n e r a l N o t e s
Note: The appliance manufacturer does not assume any
warranty for complaints attributable to the duct section.
The appliance achieves its optimum performance by
means of a short, straight exhaust air duct and as
large a duct diameter as possible.
As a result of long rough exhaust air ducts, many duct
bends or duct diameters that are smaller than 6"
(150 mm), the optimum extraction performance is not
achieved and fan noise is increased.
The ducts or hoses for laying the exhaust air line must
be made of non-combustible material.

Electrical requirements

This appliance must be properly installed and grounded
by a qualified technician in accordance with the National
Electrical Code ANSI/ NFPA 70 (latest edition) and local
electrical code requirements. IN CANADA: Electrical
installation must be in accordance with the current CSA
C22.1 Canadian Electrical Codes Part1 and/or local
codes.
The range must be connected to the proper electrical
voltage and frequency as specified on the rating plate.

For wall mounting: Checking the wall

The wall must be level, vertical and adequately load-
bearing.
Use suitable fasteners depending on the type of
construction (e.g. massive brickwork, drywall, porous
concrete, Poroton wall tiles).
The depth of the bore holes must be the same length
as the screws. The wall plugs must have a secure grip.
The maximum weight of the fan module is approx. 20 lb
(9 kg).
8