FuelTech FT INPUT Manual Do Usuário página 23

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Configuring General Inputs
d - In the General Inputs group, click on the channel to be configured.
e -
The channel configuration screen in FT Input Expander is very similar to
the screen on the FT Manager under "Sensors and Calibration / Inputs",
with a single difference which is the "Sampling rate" field. This parameter
is responsible for the frequency that the information is sent via the CAN
network.
It is divided into 4 options: 2, 10, 50 and 100 Hz.
f -
Click on the "OK" button to save the configuration.
NOTE
The FT Input Expander records at sample rates of up to 100Hz.
If you need to monitor information with rates up to 200Hz, use
a channel from your Power FT ECU itself.
FT Input Expander
EN