Compact electric heater
Start
1. Fill the pool with water to the right level.
2. Start the pump for pool water circulation.
3. Check that the water circulates as normal in the system and that all air is vented from the system.
The heater must be completely water-filled before switching on the power.
Only when all air has been vented from the system can the heater be switched on.
4. Functional test the heater by turning the thermostat knob back and forth and check that the thermostat contactor switches
and releases.
The flow monitor is checked by turning off the flow through the heater with a shut-off valve and check that the contactors
release. Turn on the water again. The contactors should then switch on again.
5. Set the desired pool temperature with the thermostat knob.
6. The water is now heated to the desired temperature.
Operation
When backwashing and cleaning the filter, switch off the power to the heater.
In the event of a risk of freezing, the power must be switched off and the heater drained of all water.
General info
In order to ensure good operation and a long heater life, it is important that the following recommended values regarding water
quality are followed.
Chlorine content:
max 3.5 mg/l (ppm)
pH-value:
7.2–7.6
Alkalinity:
60–120 mg/l (ppm)
Calcium hardness:
100–300 mg/l (ppm)
Iron:
max 0.1 mg/l *
Copper:
max 0.2 mg/l *
Manganese:
max 0.05 mg/l *
Phosphorus:
max 0.01 mg/l *
Nitrate:
max 50 mg/l *
Compact
Chloride (salt) content: max 250 mg/l
Failure to follow the limit values for water quality invalidates the product warranty.
Troubleshooting:
1. Check the fuses.
2. Check that the system has the requisite flow through the heater.
Check that a possible flow monitor is fitted so that the arrow on the flow monitor housing corresponds to the flow direction of
the water.
3. The pressostat, if fitted, is not closed:
The pressostat is preset to 0.25 bar. If the correct pressure is not reached, the return line to the pool should be throttled
slightly to increase the counter-pressure in the return line.
4. Check whether the overheating protection has tripped, investigate the cause.
After the cause has been established and rectified, the overheating
protection is reset by:
- Unscrewing the protective cap (A).
- Press in the reset button (B) on the junction box.
- Refit the protective cap again.
5. Check the operation of the heater, see point 4 under "Start".
6. Reset the thermostat to a higher temperature.
7. If the problem persists: contact the installer.
Disposal and recycling
You must dispose of this product in accordance with local laws and provisions.
Since this product contains electronic components, it must be disposed of separately from household waste.
When this product reaches the end of its life cycle, contact your local authorities to find out more about disposal and recycling.
Compact Titanium
max 35,000 mg/l
14
* According to EN 16713-3
A
B
ENGLISH
Surface treatment
Designed by:
Drawn by: Date
Approved by:
E
TS
TS
2007-12-12
The tolerance class in accordance with this
Assembly drawing no.
Art.no.
139VXYZZ
Medium
part of ISO 2768-1
Scale
Revised by: Date
Elvärmare kompakt 3-18kW
ASA 2019-07-23
Drawing number
Rev.no.
M10931 3
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880