5.0 CERTIFICATION
IECEx units
Certified to IEC60079-0, IEC60079-11 and IEC60079-26
Ex ia unit (IEC certification No. IECEx BAS 08.0043X)
Ex ia IIC T4 Ga (-20°C to +55°C)
The IECEx certificate and product label carry the IECEx equipment protection level marking
Ga
Where Ga signifies suitability for use in a Zone 0 surface industries area in the presence of gas.
ATEX units
Certified to EN60079-0, EN60079-11 and EN60079-26
Ex ia unit (ATEX certification No. BAS00ATEX1259X)
Ex ia IIC T4 Ga (-20°C to +55°C)
The ATEX certificate and product label carry the ATEX group and category marking:
II 1G
Where:
Signifies compliance with ATEX
II
Signifies suitability for use in surface industries
1
Signifies suitability for use in a zone 0 area
G
Signifies suitability for use in the presence of gases
The ATEX certificate and product label also carry the following mark:
This signifies unit compliance to the relevant European directives, in this case 94/9/EC, along with the number
of the notified body issuing the EC type examination certificate.
6.0 SPECIAL CONDITIONS FOR SAFE USE
1. By virtue of its shape, design and position of intended use, it is considered not to be an electrostatic risk,
however the apparatus must not be installed in a position where it may be subjected to an excessive dust laden
airflow
2. The equipment must only be cleaned using a damp cloth