14
VLS Series Speakers
Technical Specifi cations
VLS 7 (EN 54) / VLS 7 (EN 54)-WH
System
Frequency response
see Graph 1# as below
Horizontal dispersion (-6 dB)
Vertical dispersion (-6 dB)
+6° / -22° V (-8° bias)
150 W average, 300 W continuous,
Power handling (IEC)
600 W peak
Recommended amplifi er power
450 W @ 8 Ω
System sensitivity
90 dB (1 m, Lo Z)
Sensitivity (per EN54-24)
76 dB (4 M, through transformer)
Nominal impedance (Lo Z)
Maximum SPL (per EN54-24)
91 dB (4 M, through transformer)
Rated maximum SPL
112 dB continuous, 118 dB peak (1 m, Lo Z) 114 dB continuous, 120 dB peak (1 m, Lo Z) 120 dB continuous, 126 dB peak (1 m, Lo Z)
Crossover
Crossover point
—
Directivity factor (Q)
6.1 averaged, 1 kHz to 10 kHz
Directivity index (DI)
7.9 averaged, 1 kHz to 10 kHz
Components
7 x 3.5" (89 mm) fullrange drivers
Transformer taps (via rotary switch) (Rated noise power and impedance)
150 W (33 Ω) / 75 W (66 Ω) / 37.5 W (133 Ω) / 19 W (265 Ω) / 9.5 W (520 Ω) / 5 W (1000 Ω)
70 V
OFF & low impedance operation
150 W (66 Ω) / 75 W (133 Ω) / 37.5 W (265 Ω) / 19 W (520 Ω) / 9.5 W (1000 Ω) /
100 V
OFF & low impedance operation
Coverage angles
500 Hz
360° H x 129° V
1 kHz
202° H x 62° V
2 kHz
137° H x 49° V
4 kHz
127° H x 40° V
Enclosure
Connectors
Wiring
Dimensions H x W x D
816 x 121 x 147 mm (32.1 x 4.8 x 5.8")
Net weight
10.8 kg (23.8 lbs)
Construction
Finish
Paint RAL 9003 (white) / RAL 9004 (black) Custom RAL colours available (additional cost and lead-time)
Grille
Flying hardware
Notes:
(1) Average over stated bandwidth. Measured in an IEC baffl e in an Anechoic Chamber
(2) Unweighted pink noise input, measured at 1 metre on axis
(3) Long term power handling capacity as defi ned in IEC268-5 test
(4) The reference point for the reference axis (on-axis) is the centre of the baffl e
Frequency Response Sensitivity 1 W / 1 m
110
110
100
100
90
90
80
80
70
70
60
60
50
50
20
100
1k
10k
20k
Frequency (Hz)
Graph 1# VLS 7 (EN 54)
Graph 2# VLS 15 (EN 54)
VLS 15 (EN 54) / VLS 15 (EN 54)-WH
VLS 30 / VLS 30 -WH
120 Hz - 22 kHz ±3 dB
see Graph 2# as below
90 Hz - 35 kHz -10 dB
130° H
+6° / -22° V (-8° bias)
+3° / -11° V (-4° bias)
200 W average, 400 W continuous,
400 W average, 800 W continuous,
800 W peak
1600 W peak
600 W @ 8 Ω
1200 W @ 4 Ω
91 dB (1 m, Lo Z)
94 dB (1 m, Lo Z)
—
12 Ω
6 Ω
96 dB (4 M, through transformer)
—
Passive, utilizing Focussed Asymmetrical Shaping Technology (FAST)
2.5 kHz
9.1 averaged, 1 kHz to 10 kHz
15 averaged, 1 kHz to 10 kHz
9.6 average, 1 kHz to 10 kHz
11.8 average, 1 kHz to 10 kHz
7 x 3.5" (89 mm) woofers
14 x 3.5" (89 mm) woofers
8 x 1" (25 mm) metal dome tweeters
16 x 1" (25 mm) metal dome tweeters
150 W / 75 W / 37.5 W / 19 W / 9.5 W /
5 W / OFF & low impedance operation
150 W / 75 W / 37.5 W / 19 W / 9.5 W /
OFF & low impedance operation
226° H x 114° V
220° H x 41° V
191° H x 57° V
200° H x 21° V
131° H x 32° V
120° H x 17° V
119° H x 27° V
120° H x 20° V
Barrier strip
Terminal 1+ / 2- (input); 3- / 4+ (link)
1461 x 121 x 147 mm (57.5 x 4.8 x 5.8")
11.7 kg (25.7 lbs)
19 kg (41.8 lbs)
Aluminium extrusion
Powder coated perforated steel
Flying bracket, wall mount bracket, input panel cover plate and gland
Remark: Horizontal is defi ned as below
Frequency Response Sensitivity 1 W / 1 m
20
100
1k
10k
20k
Frequency (Hz)
Other important information
Important information
1. Register online. Please register your new
Music Tribe equipment right after you purchase it by
visiting tannoy.com. Registering your purchase using our
simple online form helps us to process your repair claims
more quickly and effi ciently. Also, read the terms and
conditions of our warranty, if applicable.
2. Malfunction. Should your Music Tribe
Authorized Reseller not be located in your vicinity,
you may contact the Music Tribe Authorized Fulfi ller for
your country listed under "Support" at tannoy.com. Should
your country not be listed, please check if your problem
can be dealt with by our "Online Support" which may also
be found under "Support" at tannoy.com. Alternatively,
please submit an online warranty claim at behringer.com
BEFORE returning the product.
3. Power Connections. Before plugging the
unit into a power socket, please make sure you are using
the correct mains voltage for your particular model.
Faulty fuses must be replaced with fuses of the same type
and rating without exception.
Quick Start Guide
15