Secondary parameters
16 Secondary parameters
 Call up the secondary parameters by pressing
button 29.
 Set the desired secondary parameter by turn-
ing control knob 19.
Depending on the selected welding process,
function and operating mode, various second-
ary parameters are available.
A description of the secondary parameters is
provided in the following table.
Code
Secondary parameters
G--
Gas pre-flow time
Start energy
StE
Hot start energy
Start time
Stt
Hotstart time
StS
Start slope time
2.E
Second energy
PuF
Pulse frequency
Pulse duty cycle (% of welding cur-
Pub
rent I
)
1
CFS
Crater filling slope time
CFE
Crater fill energy
CFt
Crater fill time
--G
Gas post-flow time
HF
HF ignition
dAF
Arc Force
AEd
Arc end detection
CEL
CEL electrode mode
Tab. 1:
Secondary parameters
04.19
 Confirm the secondary parameter by pressing
control knob 19.
9 The parameter value flashes.
 Change the value of a parameter by turning
control knob 19.
 Store the change by pressing control knob 19.
Press button 29 to terminate a change with-
out storing or to exit the secondary parameter
menu.
Standard
value
0.1 s
50 %
*
125 %
*
0.1 s
1.0 s
0.5 s
50 %
*
3.0 Hz
50 %
0.5 s
25 %
*
0.2 s
100 %
on
100 %
100 %
Off
909.4039.9-03
Setting range
0.1 to 10 s
1 - 200 %
1 - 200 %
0 - 99.9 s
0 - 99.9 s
0 - 99.9 s
1 - 200 %
0.1 Hz - 5 kHz
1 - 99 %
0 - 99.9 s
1 - 200 %
0 - 99.9 s
20 - 500 %
On - Off
0 - 200 %
0 - 200 %
On - Off
*) % of selected main current
Mode
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
- 35 -