Installation Instructions - TR11 LED
Shallow Cast Unit Installation
1.
Remove lens, using a TORX T20 center pin reject
screwdriver.
2.
Remove back plate using Philips screwdriver.
3.
Select the correct type fasteners to use for the
mounting surface, 1/4" nominal diameter (not supplied).
4.
Center cast housing on flat smooth ceiling or wall over
junction box. Use cast housing as a template to layout
fastener locations. (Figure 7 .)
5.
Remove the four donut gaskets from the supplied
square gasket set. Peel the backing from each of the
four donut gaskets and apply them to the back side of
the cast housing at each of the four mounting holes
(gasket has adhesive on one side). Use the remaining
gasket square to seal cast housing to J-Box.
6.
Connect fixture wires to the proper supply wires and
place in junction box. Minimum 90 deg. supply wire
required. Ground fixture with wire provided.
CAUTION
Do not touch LEDs on fixture, care must be taken to not
come in contact with LED bar(s) or connector(s) during
fixture installation.
7 .
Align fixture without lens to four mount holes. For wall
mounted, note the driver will be oriented at the top as
shown in (Figure 7). Tighten all four mounting fasteners
sufficiently to compress housing into gasket.
N
ote:
If mounting surface is uneven or rough, it will
be necessary to caulk around fixture to provide
water tight seal.
8.
Replace the back plate which was removed in step 2.
Replace the lens by aligning (3) lens pins and mounting
plate slots. On the plate, they should be located at the
3,9 and 12 O'clock" positions. Use 'O' ring (Supplied)
with all four screws.
N
ote:
If using eyelid option, the lens should be
attached first using the shorter screws at the
"12 and 6 O'clock" position and fastened
securely. The eyelid should then be installed
with the longer screws at the "3 and 9 O'clock"
positions and fastened securely. If using Eyelid
option make sure the eyelid is also in the "UP"
position. (Figure.5) Do not over-torque screws
during installation of lens.
Maintenance: Verify that the power is OFF.
Lens panel should be cleaned on a regular schedule (6 to 12
month intervals based on local conditions).
4
COOPER LIGHTING SOLUTIONS
IB519021EN
Installation instructions
Shallow Casting
Shallow Casting
Lens
Figure 6. Shallow Cast Unit Installation
Driver will always
be on top
Diagonal Mounting Holes
Figure 7. Shallow Cast Unit Installation
Donut Gasket
Figure 8. Shallow Cast Gasket Location
Back-Plate
Wall
Junction Box
Square Gasket
Mounting