GB
Trouble shooting
Problem
Possible cause
ON / OFF switch (10) is
turned off
Pressure
Damaged power supply ca-
cleaner is not
ble (5)
operating
Mains fault
Pressure
Air trapped in the pressure
cleaner does
cleaner
not generate
Drop in the water mains
any pressure
pressure
Severe pres-
High-pressure nozzle (17)
sure fluctua-
is dirty
tions
Connections not fitted cor-
rectly
Leaks in the
water system
Water connection leaks
Spare Parts
Spare parts and accessories can be obtained at www.grizzly-service.eu.
If you do not have internet access, please contact the Service Centre via tele-
phone (see "Sercice-Center" Page 119). Please have the order number mentioned
below ready.
High-pressure hose ......................................................................................... 91097400
Jet tube w/ high-pressure nozzle ..................................................................... 91097403
Jet tube w/ flat spray nozzle ............................................................................ 91097404
Water port w/ strainer frame ............................................................................ 91097408
Quick-action water supply connector............................................................... 91097401
Jet gun ............................................................................................................. 91097260
Rotating brush ................................................................................................. 91097405
Cleaning agent (0,5l)
24
........................................................................................ 30990010
Remedy
Check ON / OFF switch (10)
Switch off the equipment and discon-
nect from the mains. Check power
supply cable (5) for damage. If neces-
sary have the power supply cable (5)
replaced by a qualified electrician.
Check the electrical system for conform-
ity with the data on the rating plate.
Switch on the equipment with the jet
gun and with no nozzle until bubble-free
water comes out.
Check the water mains.
Rinse the high-pressure nozzle (17)
with water. If necessary clean the noz-
zle hole with a needle.
Switch off the equipment and discon-
nect from the mains. Reconnect the
equipment to the water pipes (cf. "Initial
Operation/Set-Up")
Switch off the equipment and discon-
nect from the mains. Replace the wa-
ter connection inc. gasket (cf. "Spare
Parts")