GB
User Manual
Earth (ground) Terminal
Fuse
Conforms to European Union
directives
The equipment is protected
throughout by double insulation
or reinforced insulation.
COM
Common
Specifications
Display:
Negative Polarity Indication:
Sampling Rate:
Battery:
Low Battery Indication:
IP degree:
Operating Environment:
Storage Temperature:
Accuracies specified at 18°C to 28°C with relative humidity (RH) <75%.
Accuracy specifications are calculated as
follows:
DC Voltage
Range
Resolution Accuracy
200 mV
100 µV
2000 mV
1 mV
20 V
10 mV
200 V
100 mV
300 V
1 V
Input Impedance: 1 MΩ
Max. Allowable Input Voltage: 300 V
* If the voltage being measured is > 300V, the
display may show the value of the voltage; but the
measurement is dangerous.
4
Overrange
Indication
±(0.5% + 5)
"1" shown
on the
±(0.8% + 5)
display
±(1.0% + 5) —*
3 ½-digit LCD, max reading of 1999
" – " shown automatically
Approx. 2-3 times/second
9V (6F22 or equivalent)
IP20
0°C to 50°C (<75%RH)
-10°C to 60°C (<85%RH)
±([% of reading]+[number of least significant
digits])
AC Voltage
Range Resolution Accuracy
200 V
100 mV
300 V
1 V
Frequency Range: 40 Hz - 400 Hz
Max. Allowable Input Voltage: 300 V
Response: Average, calibrated in rms of sine
wave
* If the voltage being measured is > 300V, the
display may show the value of the voltage; but the
measurement is dangerous.
Overrange
Indication
"1" shown on
the display
±(1.2% + 5)
—*