ZONE A OUTPUT SCHEDULE
The PX2 lets you precisely schedule up to six
timed output settings from the fixtures during
the light cycle (by wattage or percentage).
Checkmarks in front of the six timed output
settings provide the ability to disable or enable.
CHECK = Enabled.
and enter the ZONE A OUTPUT
1. Press
SCHEDULE menu.
2. Press
to cursor through the time and
output settings.
3. Press
or
to adjust, then press
4. Repeat steps 2–3 to set all values.
5. Press
button to save the settings.
6. Repeat steps for ZONE B.
IMPORTANT ZONE OUTPUT SCHEDULE NOTES
•
Output adjustments ONLY take effect according to OUTPUT SCHEDULE and clock setting.
•
Enabling more OUTPUT SCHEDULE settings is advisable for greater flexibility.
•
Sunrise and sunset (R/S) time setting can impact OUTPUT SCHEDULE. Ensure these two
settings do not conflict. Example: If R/S is set to 10 minutes, the timing between OUTPUT
SCHEDULE signals should be set no less than 10 minutes.
Indicator Meaning
LED on green: Normal status. Screen display: NML
LED on yellow: Over-temperature dimming protection. Screen display: DIM
LED flashes red: Over-temperature lamp-off protection or temperature exceeds 80°C.
A, C
Screen display: SOS
LED flashes yellow: Temperature control line is not inserted. Screen display: NO PROBE
LED LIGHT ON: Lamp on. LED LIGHT OFF: Lamp off.
B, D
If the ANALOG indicator is on, the controller outputs 0–10V signals for LED, 0–11.5V for HID.
E
If the DIGITAL indicator is on, the controller outputs RS485 signals.
F
The ANALOG and DIGITAL indicators are both on.
E, F
ZONE A is the analog signal output, and ZONE B is the digital signal output.
The output signal mode can be switched by clicking the SET button with a pen.