OPERATING INSTRUCTIONS
PRODUCT SUMMARY
This mechanical timer can be configured for various voltages: 120/VAC, 208VAC, 240VAC
and 277VAC. Selecting the desired voltage is done so by simply positioning the dip switch
to the required voltage. This unit features a NEMA 3R indoor/outdoor enclosure. Some
uses include: lighting, heating, air conditioning, pumps, motors or general electrical
circuits in residential, commercial, industrial and agricultural facilities. Switch Rating: DPDT
SPECIFICATION
Min. Time Interval – 15 minutes
On/Off per day – 48
Box Type - N-3R Non-Metallic Enclosure

TECHNICAL INFORMATION

• 120-240VAC, 60Hz, 40A resistive
• 277VAC, 60Hz, 30A resistive
• 14VDC, 30A resistive
• 120VAC, 1HP, 10A Ballast
• 208-240VAC, 2HP, 5A Ballast
• 277VAC, 1HP, 5A Ballast
• 120VAC, 8.3A Tungsten
• 208-277VAC, 5.4A Tungsten
• 120VAC, 800VA Pilot Duty
• 208-277VAC, 720VA Pilot Duty
• TV-5
• Max programs per day: 48 ON/OFF
• With power and load indicator
• With ON/OFF/ Timing manual switch
• Min. Setting me: 15 minutes
• Max. Setting me: 24 HR
• Environmental rating: -40 F to 130 F
• Humidity:0-95%
READ INSTRUCTIONS CAREFULLY IN ORDER
TO SET UP YOUR OUTDOOR TIMER PROPERLY
INSTALLATION
Before wiring or service, power to
this time control and the equipment it
controls must be turned off, turning off
the time control only will not prevent
a shock hazard. Supplying power to
time control, installation should be
performed by a licensed electrician only.
Before installing this product read
all instructions carefully. Choose the
appropriate KO's according to the cable,
wire size and direction.
Optional external mounting tabs are
provided as following:
Remove protective cover panel in time
control housing by pressing the clip at
the bottom of cover panel.