Basement Sentry STBC201 Instrucciones De Instalación página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

START-UP AND OPERATION
5. Lift the lower (operational) float on the backup pump float
switch. After one second, the backup pump will run and
the alarm will sound. Be sure the inlet of the backup
pump is above the inlet of the primary pump. Press
'Silence' for 3 seconds to cancel the alarm and reset the
unit.
CAUTION: Continuously running the pump dry may
cause overheating and damage the pump. Once the
lower float is released, the backup pump will run for an
additional ten seconds or until it senses that water is no
longer being pumped.
6. Lift the upper (high water) float on the backup pump
float switch. After one second, the backup pump will
run and the alarm will sound. Be sure the inlet of the
backup pump is above the inlet of the primary pump.
Press 'Silence' for 3 seconds to cancel the alarm
and reset the unit.
CAUTION: Continuously running the pump dry may
cause overheating and damage the pump. Once the
upper float is released, the backup pump will run
for an additional ten seconds or until it senses that
water is no longer being pumped.
Be sure there are no obstructions around the float.
7. Complete the final test of the installation. Be sure
the primary pump is still disconnected from power.
Unplug the controller from the 115V outlet. Run
water into the sump basin until the backup pump
turns on. Check all connections for leaks.
5
6
7
17
© 2020. All rights reserved.
Lift
lower
float
to test
Lift
upper
float
to test
Unplug
controller to test
by
AC
FLOAT
POWER
STATUS
TEST
24/7 BASEMENT
PROTECTION
BATTERY
DC
PUMP
SILENCE
USB
1-800-584-8089
DC POWER
BasementSentry.com
DC
FUSE
+ 15V DC 1.6A
RESET
FLOAT
PUMP
30 AMP

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido