Installation and start-up
Placement
For safety and operational reasons, the
appliance must not be installed outdoors.
The appliance should be placed on a level
surface in a dry, well ventilated room (max.
75% relative air humidity). Never place the
appliance close to sources of heat such as
cookers or radiators, and avoid placing it in
direct sunlight.
Room temperature
The climate class is stated on the
nameplate (see fig. 1 on page 3 and fig. 13
on page 15). This specifies the optimum
room temperature.
Climate class Optimum room tem-
perature
SN
+10 ºC to +32 ºC
N
+16 ºC to +32 ºC
ST
+18 ºC to +38 ºC
T
+18 ºC to +43 ºC
Installation
The surface on which the appliance is to be
placed must be level. Do not use a frame or
similar.
The appliance can be installed as a free-
standing unit against a wall or built into a
kitchen element (fig. 2). If two appliances
are placed side by side, there must be at
least 30 mm clearance between them (fig.
3).
After installation, the plug should be
accessible.
600
600
600
600
4
600
fig. 2
30
600
fig. 3
600