INSTALLATION

INSTALLATION LOCATION RECOMMENDATIONS

Thermostat should be mounted:
• On an interior wall, in a frequently occupied space .
• Approximately 5' above floor .
• At least 18" from outside wall .
• Thermostat can be mounted to a vertical junction box .

OUTDOOR TEMPERATURE SENSOR (INCLUDED)

Outdoor temperature can be measured by attaching the included 8052 sensor to the S1 and S2 terminals . The
outdoor sensor must be enabled in the installer setup menu .
Heat pump models can use the outdoor temperature to effectively utilize the heat pump:
• When the outdoor temperature is less than the Low Balance Point, the heat pump will be locked out and only
auxiliary heating will be used .
• When the outdoor temperature is higher than the High Balance Point, the auxiliary heating will be locked out and
only the heat pump will be used to provide heating .
Indoor Air Quality functions can use the outdoor temperature sensor to:
• Control humidification setpoint based on outdoor temperature to prevent condensation
• Lock out humidification for temperatures over 60°F or below -30°F .
• Lock out ventilation based on high and/or low outdoor temperatures .
• Display outdoor temperature on thermostat .
Outdoor temperature sensor should be mounted:
• On side of building out of direct sunlight (north side recommended) .
• Above snow line .
• At least 3' away from exhaust vents and condensing lines .
• Using less than 300' of wire .
• Do not route wires along 120 VAC lines .
I2
2 English
Do not mount thermostat:
• Behind doors, in corners or other dead air spaces .
• In direct sunlight, near lighting fixtures, or other
appliances that give off heat .
• On an outside or unconditioned area wall .
• In the flow of a supply register, in stairwells, or near
outside doors .
• On a wall with concealed pipes or ductwork .
C
I1 O/B Y Y2 G
RC
R
W2
W
L S2
S1
T1
INSTALLATION

REMOTE TEMPERATURE SENSOR (OPTIONAL)

A remote temperature sensor can be used if the thermostat has to be mounted in a concealed location . A 8051 flush
mount or 8053 surface mount remote temperature sensor can be attached to the T1 and T2 terminals and mounted
in a recommended area . The remote sensor must be enabled in the installer setup menu . When the remote sensor is
installed it overrides the internal sensor .
Remote temperature sensor should be mounted:
• On an interior wall, in a frequently occupied space .
• Approximately 5' above floor .
• At least 18" from outside wall .
• Using less than 300' of wire .

THERMOSTAT MOUNTING

1 . Remove the rear mounting plate from the thermostat .
2 . Pull wires through the opening on the back of the
thermostat .
3 . Position and level the mounting plate of the thermostat
on wall and mark the hole locations with a pencil .
4 . Drill 1/4" holes and insert supplied anchors
(drywall only) .
5 . Place mounting plate over anchors, insert and tighten
screws .
6 . Seal wire entry holes to prevent drafts affecting
temperature readings .
T2
Do not mount remote sensor:
• Behind doors, in corners or other dead air spaces .
• In direct sunlight, near lighting fixtures, or other
appliances that give off heat .
• On an outside or unconditioned area wall .
• In the flow of a supply register, in stairwells, or near
outside doors .
• On a wall with concealed pipes or ductwork .
• Near 120 VAC lines .
I2
C
I1 O/B Y Y2 G
RC
R
W2
W
L S2
S1
T1
T2
English 3