4
Full manual is available on
our website and download the manual.
The ETHM-1 Plus module enables the INTEGRA Plus, INTEGRA and VERSA alarm control panels to
communicate via the Ethernet network.
You can connect the INT-GSM / INT-GSM LTE module to the ETHM-1 Plus module. This will
allow the cellular data network to be used as a backup communication path and enable dual
path reporting.
1. Electronics board
The electronics board is shown in Figure 1.
terminals:
+12V
- +12 VDC power input.
COM
- common ground.
TMP
- tamper input (NC) – if not used, it should be shorted to common ground.
A RS485 B - RS-485 port for connecting INT-GSM / INT-GSM LTE module. The INT-GSM /
DTM
- data (communication bus).
CKM
- clock (communication bus).
RS-232 port.
PWR/LOG LED:
OK – power OK,
flashing – communication via the module in progress.
BUS LED – blinking LED indicates that data exchange with the control panel is in progress.
pins for setting the module address (see "Setting address").
RJ-45 connector for Ethernet network. It is provided with two LEDs:
green – ON when the module is connected to the network,
yellow – flashes during data transmission.
2. Setting address
To set an address, you must place jumpers across the ADDRESS pins. Table 1 shows how to use
jumpers in order to set a specific address ( - jumper on;
Address
Pins status
2.1 Module connected to INTEGRA / INTEGRA Plus control panel
Set an address in the module within the range:
•
from 0 to 3, if it is connected to INTEGRA 24 or INTEGRA 32 control panel,
•
from 0 to 7, if it is connected to another INTEGRA or INTEGRA Plus control panel.
Quick installation guide
www.satel.eu.
INT-GSM LTE module is supported if the ETHM-1 Plus module is connected to
the INTEGRA Plus / INTEGRA (required control panel firmware version: 1.19 or
newer).
0
1
ETHM-1 Plus
Scan the QR code to go to
- jumper off).
2
3
Table 1.
4
5
6
SATEL
7