Mechanical Specifications; Electrical Specifications; Operating Limits; Electric Shocks - PCE PAC 20 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4.4/ MECHANICAL SPECIFICATIONS

- Watertightness:IP 30 in accordance with IEC 529
- Clamping diameter:1 cable ∅ 39 mm (or 2 cables ∅ 25 mm)
1 busbar of cross section 50 x 12.5 mm
- Outside dimensions of clamp:237 x 97 x 44 mm
- Fitted lead:1.5 m
- Weight:440 g
- Drop height:to IEC 68-2-32
- Protection from shocks:100 g to IEC 68-2-27
- Vibrations:to IEC 68-2-6
- Protection from shocks:IK04 0.5 J in accordance with EN 50102

4.5/ ELECTRICAL SPECIFICATIONS

Power supply: 9 V battery (type 6LR61, 6LF22 or NEDA 1604)
Battery life: approx. 120 hours with an alkaline battery.

Operating limits

On DC current: 3000 A permanent
On AC: 1000 A permanent up to 1 kHz
The max permitted AC overload current from 1 kHz is defined in
accordance with the following formula:
1000
Ip max =
F (kHz)

Electric shocks

Instrument with dual insulation or strengthened insulation in
accordance with IEC 61010-2-032.
Between the primary, the secondary and the hand-held part located
below the guard, dielectric test voltage: 7850 V DC.
Maximum common mode voltage between the conductor on which
the measurement is made and the earth, or the output and the
earth:600 V for installations of category III and degree of pollution
2.
Installation category and degree of pollution in accordance with IEC
664 and 664A
4.6/ ÉLECTROMAGNÉTIC COMPATIBILITY
Emissions and immunity in an industrial setting compliant with IEC
61326-1.
14

Publicidad

Tabla de contenido
loading

Tabla de contenido