Figure 3
Water
Figure 4
INSTALL UPPER PLATE GUIDE
With top cover open, slide the upper plate guide under
the white wheel.
NOTE: Flange should face up and toward tape
compartment. (See Figure 5)
Figure 5
INSTALL WEIGHT
1.
For lighter paper tapes (60/70 grade), remove
the weight. For heavier paper tapes (70+ grade),
remove and reposition the weight so the bent part
fits over the front of the top heater. (See Figure 6)
NOTE: Paper jams often result from the weight
not being removed.
2. Take the weight assembly and slide the notches over
the pivot shaft on the water reservoir. (See Figure 7)
PAGE 3 OF 15
SET-UP INSTRUCTIONS CONTINUED
Min.
Med.
Max.
Figure 6
Weight
Set Screw
Cover Plate
Figure 7
LOAD TAPE ROLL
1. Adjust roll guide plates to fit tape width. (See Figure 8)
2. Reposition the roller for gummed in or gummed
out tapes.
3. Insert tape roll between guide plates and over roller
so tape is positioned gummed side down. Feed the
tape under the upper paper guide and white wheel
so tape end extends out under cover plate and
weight. (See Figures 8A and 8B)
Figure 8
Figure 8A
GUMMED OUT
Figure 8B
GUMMED IN
0621 IH-2243