Start-up
Battery
Only use genuine Würth Li-ion
batteries.
Note
Charge the battery before putting it
into operation for the first time.
Note
Make sure the battery is properly
seated in the device before use.
If used properly, the battery can be recharged
■
up to 1,000 times.
Five charging / discharging cycles are required
■
for the battery to reach its full performance po-
tential. This also applies to batteries which have
not been used for an extended period of time.
Never discharge the battery completely.
■
Service life can be extended by regularly using
■
and subsequently recharging the battery.
If the battery is not inserted into the charger
■
during storage, do not forget to recharge the
battery from time to time.
If, despite recharging, the battery life is getting
■
significantly shorter, the battery is exhausted
and needs to be replaced.
Indicator lights:
Steady green:
Battery is charged/conserva-
tion charging mode
Blinking green:
Battery is being charged
Steady red:
Charging temperature not
admissible
Blinking red:
Defective battery
Adjusting the length x of the threaded
mandrel (fig. I)
Adjust the length x of the threaded mandrel to
■
the rivet nut length by turning the mouthpiece
[2].
In case of closed end rivet nuts use full length of
■
thread.
Lock mouthpiece [2] with lock nut [3] against
■
shifting.
14
Adjusting the stroke y (fig. I)
The stroke y depends on the blind rivet unit size
■
(M3 – M10) and the grip range z.
Recommended values for stroke y
Thread size
Stroke y
min
M3
1
M4
1
M5
1.5
M6
2.5
M8
2.5
M10
3
The stroke y is adjusted by screwing in or out
■
the adjustment nut [4].
Note
Set the stroke y to min at the begin-
ning, then set a rivet nut.
If the blind rivet nut does not form a distinctive
■
head, the stroke y is to be enlarged step by
step.
Lock adjustment nut [4] with lock nut [5]
■
against shifting.
Screwing in a rivet nut
Place the rivet nut without tilting on the end of
■
the threaded mandrel [1].
Keep trigger [11] pressed until the tool comes
■
to a stop, then release it.
Hold the rivet nut tight during the entire proce-
■
dure.
If the rivet nut is not in tight contact with the
■
mouthpiece [2], repeat this procedure. For this
purpose hold the blind rivet nut tight, and a
short quick touch of the trigger [11] will induce
the threading out procedure.
Start again!
■
(in mm)
max
2
2
2.5
3.5
3.5
4