Descargar Imprimir esta página

Stid ARCS-X/PH5 Procedimientos De Instalación página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

ARC 13.56 MHz
Upgradable readers
Installation instructions
ARCS-X/PH5
X:
A: Standard
B: Keypad
C: Touch Screen
ARCS-X/BF5
X:
I / IM: Standard + 125 kHz module
J / JM: Keypad + 125 kHz module
K/ KM: Touch Screen + 125 kHz module
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main supply.
Main power supply:
Max. consumption at 12 Vdc:
ARC-A/PH5: 130 mA
ARC-F/PH5: 350 mA
ARC-K/BF5: 230 mA
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock and Data)
Connection:
Removable connectors 1x10 pins and 1x2 pins, thread 0.19685 inch
Protection:
IP65 classified reader
Static relay:
ASSR-1218-003E: 60 V output withstand voltage / 0.2A current rating / low on-resistance 1 Ω typical for AC/DC
RS485:
RS232:
Wiegand / Clock & Data:
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (SCB / OCB) or controlled by the remote system with a 0 Vdc
respectively on the "Led 1", "Led 2" and "Buzzer" inputs of the reader's connector or controlled by the communication protocol of the reader (SSCP
Tearing is detected by an accelerometer. When the reader is wrenched, the switch output (connector J2) provides an O/C contact to indicate the tearing of reader.
for R/S 31/x1: the wrenching signal will be emitted on the "Data/Data1" line. This function is configurable via a configuration card.
for R/S 32/33/x2/x3 and OSDP
for W 32/33/x2/x3: the reader will perform the operations configured with the SSCP
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
Read-only reader: automatic tamper management (except touch screen) or activated on the reading of a valid identifier
Touch screen read-only reader: if the bell is activated, contact J2 is used to connect the external ring (max. 200 mA at 28 Vdc).
Read/Write & OSDP
readers: the relay is controlled by the SSCP
TM
Reader powered off. The defaults reader settings can be stored in internal memory accessible by UHF RFID technology. They will be taken into account when the
reader is powered on.
R and S readers are configurable with SCB RFID configuration card.
OSDP
TM
readers are configurable with OCB RFID configuration card or with FileTransfer command.
If the SCB/OCB is compatible with the reader's firmware, the LED lights green and the buzzer beeps five times.
If the SCB/OCB is not compatible with the reader's firmware, the LED lights red and the buzzer is activated for 1 s.
If the SCB/OCB key is different from the reader's key: no reaction.
Caution: set your reader with your own company key.
On power-up, the reader enters an initialization phase:
1.
Activation of the white LED and buzzer for 100 ms.
For read-only and OSDP
TM
readers:
2.
Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3.
For serial R/S ARC only: the orange LED flashes 20 times: waiting for an update.
4.
Activation of the default LED (read-only: flashes blue, OSDP
5.
For the ARC screen with an activated keypad, the default mode is displaying the picture on standby and activate the keyboard by pressing the screen.
▪ For optimal operation, the biometric sensor must be free of all traces of water. Outdoors it is recommended to install the reader under cover.
▪ The keypad is sensitive. Take off your gloves to enter your code.
STid reserves the right to make change without notice, for the purpose of product improvement.
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J2: O/C contact
Range: +7 Vdc to +28 Vdc
ARC-B/PH5: 160 mA
ARC-I/BF5: 160 mA
ARC-KM/BF5: 240 mA
Use a multi-conductor shielded twisted pair cable. Max. length: 3281 ft at 9600 baud
Max. length 49.2 ft
Use an untwisted shielded multi-conductor. For data:
2 wires AWG24 – 98 ft max / 4 wires AWG24 – 197 ft max / 6 wires AWG24 – 328 ft max
2 wires AWG20 – 164 ft max / 4 wires AWG20 – 328 ft max
TM
: the reader will perform the operations configured with the configuration card.
Precautions for the biometric sensor and keypad
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1097C16 - Page 1 sur 15 - Ed. 30/06/2021
ARC 13,56 MHz
Lecteurs évolutifs
Notice d'installation
Product references
D: Standard + Biometrics
E: Keypad + Biometrics
F: Touch Screen + Biometrics
Connector
J4
1
2
3
4
5
6
7
8
9
10
Power supply characteristics
Typical: 12 Vdc
ARC-C/PH5: 200 mA
ARC-D/PH5: 280 mA
ARC-IM/BF5: 170 mA
ARC-J/BF5: 190 mA
ARC-AQ/PH5: 260 mA
ARC-BQ/PH5: 290 mA
Characteristics
Recommended cables
Buzzer / LED
Anti-tearing
®
protocol.
Relay
/ OSDP
protocol commands.
®
TM
UHF default configuration settings
Read-only reader configuration
Powering-up the readers
: off; if no customer specific configuration).
TM
ARC 13.56 MHz
Lectores escalables
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
AQ: Standard + QR Code
BQ: Keypad + QR Code
CQ: Touch Screen + QR Code
Type
Wiegand
Clock & Data
0 Vdc
+Vcc (+7 Vdc to +28 Vdc)
D0
Code
D1
Data
Clock
Clock
NC
NC
NC
NC
Led 1
Led 2
Buzzer
ARC-E/PH5: 310 mA
ARC-JM/BF5: 200 mA
ARC-CQ/PH5: 330 mA
US
FR
ES
RS232
RS485
NC
NC
NC
NC
NC
NC
Tx
L+
Rx
L-
/ OSDP
).
®
TM

Publicidad

loading

Este manual también es adecuado para:

Arcs-x/bf5