ARC 13.56 MHz
Upgradable readers
Installation instructions
▪ The supply voltage at the reader's connector should be between +7 Vdc and +28 Vdc.
▪ As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level and
the proximity of the reader.
▪ Recommended distance between two readers: parallel plane: 11.8 in – same plane: 15.8 in – perpendicular plane: 9.8 in.
▪ Place the reader at a height of less than 2 meters / 78.74 inch (standard UL/IEC 62368).
▪ If the reader is fixed on a metal surface, it is possible to have a reduction in the reading distance.
▪ Use a ferrite (two-way) for the cable (power supply and data). Example: reference 74271222 WURTH ELEKTRONIK.
▪ By design, the reader can be installed indoors and outdoors.
▪ BEFORE powering on, connect the wires or the connector of the reader. Before disconnecting the wires or the connector of the reader, power off.
▪ Operating temperature:
Temperature
Readers
For data signals, 10k pull-up resistors are connected internally to V
Available Baud rate
Factory Baud rate
Mode
Number of bits
Transfer mode
Stop bit
RS485
Wiring resistors R1 and R2 use extended features
of the RS485 bus: FAIL-SAFE (see RS485-AN-960).
R1 & R2: 1.5 kΩ resistor supplied.
R
: 120 Ω end-of-line resistor supplied
T
Version 1
General tolerance following ISO NFT 58-000 standard.
STid reserves the right to make change without notice, for the purpose of product improvement.
ARC 13,56 MHz
Lecteurs évolutifs
Notice d'installation
-22 °F to 158 °F
-22 °F to 140 °F
-30°C to +70°C
-30°C to +60°C
A, B, IM, JM
AQ, BQ
in
RS232 / RS485 communication
9600, 19200, 38400, 57600, 115200 bauds
ARC R & S: 9600; ARC W: 38400 (SSCP
Default broadcast address 00h
Smart mounting plate dimensions
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1097C16 - Page 2 sur 15 - Ed. 30/06/2021
Precautions for installation
-4 °F to 158 °F
-20°C to +70°C
C, I, J, K, KM
TTL pull-ups
(power supply voltage) for optimal wiring distances.
®
), 9600 (OSDP
Asynchronous
8
LSB first
1
Bus architecture (RS485)
Version 2
Scalability
Scalability is a specific feature of the Architect® series.
Each reader is composed of three parts: one switchable
cover, one RFID core and one smart mounting plate.
You can upgrade functionalities and security levels by
switching the cover and/or adding a biometric, 125kHz
or QR Code module.
ARC 13.56 MHz
Lectores escalables
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
-4 °F to 140 °F
14 °F to 122 °F
-10°C to +50°C
-20°C to +60°C
CQ
D, E, F
TM
)
More
reader
are
available
protocol specification
US
FR
ES
details
about
communication
in
the

Publicidad

loading

Este manual también es adecuado para:

Arcs-x/bf5