INSTRUCTIONS FOR USE AND CLEANING
IMPORTANT: FOR CORRECT INSTALLATION AND USE, REFER TO THE
TECHNICAL DATA OF YOUR PRODUCT. PLEASE CHECK THE SERIAL
NUMBER LABEL FOR THE DATA RELEVANT TO YOUR PRODUCT

INSTALLATION INSTRUCTIONS

FITTING THE BUILT-IN OVEN IN CABINET:

The oven can be installed in a column unit or under the worktop of a kitchen unit.
The dimensions of the opening to be made in the cabinet for fitting the oven are given in fig. 1. Make sure the
cabinet in which the oven is to be installed can take the weight of 45 kg for DPM 86 M and MAM 82 M.
The respective dimensions of the type of oven for the opening in the cabinet are given in Fig. 1 for FI 90
(90x48). Make an opening at the bottom of the cabinet or in the oven support shelf, at the back, see fig. 1, to
allow air to enter and therefore the recirculation of air for cooling the oven during use.
Make sure the oven is securely fitted in the cabinet. Use the screws "A", fig. 2, to fix the oven.
CABINET REQUIREMENTS The cabinet technical requirements are as follows;
- The cabinet and its components must be able to withstand a temperature of 150 °C without any
deformation and/or surface defects.
- The cabinet must allow sufficient room for the electrical connections.

OVEN ELECTRICAL CONNECTION

IMPORTANT.

- The oven must be connected by a specialised and/or authorised electrician.
- Connection must be carried out in compliance with the current European regulations.
- The electrical connection is single-phase 220 – 230 – 240 V ~ 50/60 Hz. Check the Product Label for the
correct electrical power voltage and frequency.
THE EARTH CONNECTION IS COMPULSORY.
- In case of direct connection to the mains, a double-pole switch suitable for the oven power, with contact
opening of at least 3 mm, must be installed in accordance with the current regulations.
- THE EARTH WIRE MUST NOT BE INTERRUPTED BY THE SWITCH.
THE OVEN MUST ALWAYS BE DISCONNECTED FROM THE POWER SUPPLY BEFORE
CARRYING OUT ANY MAINTENANCE AND/OR ADJUSTMENTS.
The oven may come with an electrical cable without a plug. If fitting the plug, it must adequate for the max. oven
power. Ensure correct connection of the earth wire (yellow/green) to the corresponding terminal in the plug.
If fitting or replacing the electrical cable, proceed as follows:
- Switch off or disconnect the power supply.
- Open the terminal block cover (fig. 3 and 4).
- Connect the electrical cable terminals as shown in figure 4, remembering that the yellow/green wire is the
earth. If using a 13A BS. 1363 approved plug, fit a 13 amp fuse.
- The electrical cable must be secured by the cable clamp (fig. 4) on the terminal block so that it cannot turn
and/or become detached. No part must be in contact with temperatures above 75 °C.
- The plug for the electrical connection must be suitable for the power of the oven. Also, the electrical plug
must be arranged for easy access after oven installation. In case of direct connection to the mains, install
a double-pole switch with opening of at least 3 mm for each contact.
IMPORTANT: Use type H05RR-FH 3 x 1.5 flexible electrical cable with three terminals.