Operation (continued)
2
Removing the quick connecting
hose
CAUTION: Use caution when removing the quick
connecting hose connections in order to prevent cutting
your hands.
□
If it is necessary to remove the quick
connector, push the quick connecting hose (I)
up, hold the housing together and pull down.
Care and Cleaning
□
To clean, wipe down with a damp cloth and towel dry.
□
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.
Troubleshooting
NOTE: Refer to the service parts section in this manual for a
detailed drawing showing the location of the parts listed below.
Problem
There are leaks from the
handle.
The aerator leaks or has a
reduced water flow.
The spout leaks.
The sink drain at the base of
the sink is leaking.
The water will not shut off
completely.
Possible Cause
□ The bonnet nut is loose.
□ The O-ring on the cartridge is
dirty or damaged.
□ The aerator is dirty or mis-fitted.
□ The cartridge may be clogged.
□ The retainer nut is loose.
□ The sink surface is rough or
irregular.
□ The locking nut is loose or
cartridge is not positioned
correctly.
1
□ Tighten the bonnet nut.
□ Clean or replace the O-ring.
□ Remove the aerator and check for debris.
□ Remove cartridge and check for debris.
□ Ensure the aerator is properly installed.
□ Tighten the retainer nut.
□ Apply additional silicone sealant to the
beveled side of the drain flange.
□ Retighten and test for leaks.
□ Remove the cartridge to check the rubber
seat and spring.
□ Tighten the lock nut.
□ Clean or replace.
9
Please contact 1-855-HD-GLACIER for further assistance.
2
3
Solution
HOMEDEPOT.COM/GLACIERBAY