Technical data
Voltage supply
Continuous current consumption < 150 mA
Peak current consumption
Number of relays
Contact rating of relays
Switching power
Data retention on power cut
Protective system
Operating temperature range
Relative humidity
(non-condensing)
Cable length
Recommended cable
Max. conductor cross section
(screw terminals)
Mounting of control unit
34
Wall terminal Dialock - status: 12.2006 - 732.29.125
125_WL_Buch.indb 34
Mounting and Operating Instructions
DC voltage
9 - 40 V
AC voltage
8 - 36 V
300 mA
4
DC voltage
max. 60 V
AC voltage
max. 125 V
Peak current
max. 2 A (1s max.)
Continuous current max. 1 A
max. 30 W / max.60 VA
10 years
Reader unit IP 65
Control unit IP 20
Reader unit
-20 °C ... + 70 °C
Control unit
-20 °C ... + 70 °C
0 - 95 %
(reader - control unit) max. 50 m
J-Y(St)Y 2 x 2 x 0.8
Reader unit
1.0 mm
Control unit
2.5 mm
Top-hat rail to DIN EN 50 022
2
2
05.12.2006 17:11:02