Wall-mounted installation

Fix the box and the measuring chamber on the wall (optional). The box must be installed in the equipment room (dry, temperate,
ventilated). Caution, acid vapours can cause irreversible damage to your device. Position the treatment product tanks accordingly.
The AquaRite LT must be fitted a minimum horizontal distance of 3.5 m (or more, if required by local regulations) from the pool,
within 1 m of a protected outlet and within 4.5 m of the planned cell location.
The box must be placed vertically on a flat surface, with the cables downwards. As this box is also used to evacuate heat (heat
dissipation from internal components), it is important that the four sides of the box remain unobstructed. Do not to install the
AquaRite LT behind a panel or in an enclosed space.
Before installing the control unit in the intended location, check that the power cord can reach the protected outlet and that the cell
cable can reach the intended cell location.
Disconnect the pool filtration pump before starting the installation. The system must be installed in accordance with the standards
currently in force in the country of installation. The control box must be fitted a minimum horizontal distance of 3.5 m (or more, if
required by local regulations) from the pool, within 1 m of a protected outlet and 4.5 m of the planned cell location. Install and use the
product at an altitude below 2000 m.
The flow switch must be installed on the return pipe directly in line with and upstream of the cell and the treatment product injection
point. Allow a 25 cm straight section before the flow switch. A hole should previously have been drilled in the pipe to allow the flow
switch to pass through. Screw the flow switch into the saddle clamp, taking care to seal with Teflon. Then install the clamp on the pipe.
The flow switch must be installed in the direction of operation to ensure that it is tripped by the flow from the filtration pump.
All the metal components of the swimming pool can be connected to the same earth as per local regulations.
USE ONLY GENUINE REPLACEMENT PARTS