Descargar Imprimir esta página

Festo SEC-AC Manual De Instrucciones página 2

Publicidad

Motor controller
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This product is listed by Underwriters Laboratories Inc.
(UL). Representative samples of this product have been
evaluated by UL and meet applicable UL requirements.
UL approval information
Product category code
NMMS (USA) or
NMMS7 (Canada)
File number
E198574
Considered standards
UL 508C,
C22.2 No. 14-M95
UL mark
Product category
Ind. Cont. Eq.
(Industrial Control Equipment)
Control number
1UD1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fitting and commissioning to be carried out by qualified
personnel only in accordance with the operating in-
structions.
Such qualified personnel must have several years of
training and experience in installing and commissioning
electrical and pneumatic industrial control systems.
• Please observe the applicable safety requirements
and standards.
Internal Overload Protection
• Make sure that the internal overload protection ope-
rates at 225 % of the Motor Full Load Current after
10 seconds.
For information on 'Setting the current limit values' see
'Commissioning SEC-AC' (type P.BE-SEC-AC-SW-..).
Differing or additional technical specifications
SEC-AC-305
SEC-AC-508
Power supply V
230 V
, 50/60 Hz,
400 V
, 50/60 Hz,
rated
AC
AC
1 phase
3 phase
Fuse size
1 x 16 A
3 x 16 A
Rated output
1000 VA
4000 VA
(with AC supply)
Rated current per phase
5 A
(full load)
8 A
(full load)
eff
eff
(0 ... 230 V
, 3 phase,
AC
0 ... 1000 Hz)
Ambient air tempera-
0 °C ... 40 °C,
0 °C ... 40 °C
ture (Moisture conden-
output reduction
sation is not permitted
30 W/°C as from
during operation.)
35 °C
Enclosure
IP 20 (according IEC 60 529)
To be used in a Pollution Degree 2 envi-
ronment only.
The terminal tightening torque of all Sub-D plug connec-
tors is 0.5 ... 0.6 Nm.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wire types and wiring the connections
In the following an overview of wire types is given accor-
ding to the American Wire Gauge (AWG):
Connector
[X1]
control wiring
[X2], [X10],
signal wiring,
[X11]
encoder supply wiring
[X12]
external braking resistor wiring
[X5]
RS232 interface wiring
[X6]
motor supply wiring, motor
temp. sensor and brake (option)
[X9]
power supply wiring,
24 V DC supply wiring
Use 60/75 or 75 °C copper (Cu) wire only.
For information on 'Wiring the connections' see 'Commis-
Note
sioning SEC-AC' (type P.BE-SEC-AC-SW-..), chapter 3.4
and particularly chapter 3.4.1.
en
Wire type
AWG 23
AWG 20,
AWG 25
AWG 20
AWG 25
AWG 15 (shielded),
AWG 18
AWG 15,
AWG 20

Publicidad