AC Current Measurement
1. Set the rotary switch to proper current range.
2. Press the lever to open the transformer jaws, center the conductor
within the transformer jaw. Please only measure one conductor at a
time.
3. The measured value shows on the display.
!
WARNING
•Select the highest range if the value scale to be measured is
unknown, then adjust the rotary switch until get satisfactory
resolution.
•To avoid harms to you or damages to the Meter when measuring
exposed conductor.
Measuring Resistance
1. Plug the black test lead into the COM terminals and the red test lead
into the INPUT terminals
2. Set the rotary switch to
the test leads to the object being measured.
3. The measured value shows on the display
!
WARNING
•At the manual range mode, when only "OL" is shown on the
LCD, it means the measurement has exceeded the range. A higher
range should be selected.
•When measuring in-circuit resistance, make sure that the power of
the circuit under test has been turned off and that all capacitors
have been fully discharged.
press SEL button switch to Ω, Connect
7