The MAGIC VAC
®
does not work
• Make sure that the ON(I)/OFF(0) switch (8) has been
pressed properly to allow the appliance to work. The
green light should be on.
• Make sure the MAGIC VAC
properly. Check the electric socket by plugging
another appliance into it.
• The MAGIC VAC
®
will stop automatically if overheat-
ed. Allow it to cool down for 15 minutes and try
again.
• Check for faults in the power cord or the plug.
Should you detect a fault, do not use the appliance.
The MAGIC VAC
fails to apply the first seal on the bag
®
cut from the roll
• Make sure the bag cut from the roll is properly posi-
tioned as described in the paragraph: "Making bags
from MAGIC VAC
rolls"
®
The MAGIC VAC
®
does not create a complete vacuum in
the bags
• The Sealing Time knob (5) might have been positioned
on too low a setting during the first sealing operation.
The Sealing Time knob (5) should be positioned
between "5" and "7". Carry out a second sealing oper-
ation along the same line and repeat the vacuum-
forming process.
• It might be necessary to raise the Vacuum Level (2) to
a higher setting; Turn the Vacuum Knob (2) clockwise
to increase the vacuum.
• To seal the bag properly, you must make sure that the
open end remains completely inside the Vacuum
Chamber.
• Make sure that the Sealing Bar, the Sealing Gaskets
and Airtight Gaskets are free of impurities. After
cleaning them, put them properly back in place.
• The MAGIC VAC
®
bag might have a hole in it. To
check the bag, seal it with air inside, place it under-
water and apply pressure on it. The appearance of
bubbles means that there is a leak. Reseal or use
another bag.
The MAGIC VAC
®
does not seal the bag properly
• Whenever the machine does not seal the bag com-
pletely, turn the Sealing Time knob (5) clockwise to
increase the sealing time. not seal the bag properly.
• If the Sealing Bar overheats and melts the bag, you
may have to raise the Lid and allow the Sealing Bar to
cool down for a few minutes.
• The MAGIC VAC
®
is built in conformity with current
safety standards. Overheating will cause it to turn off
automatically. Allow the appliance to cool down for
15 minutes and try again.
TROUBLESHOOTING
®
has been plugged in
The MAGIC VAC
®
bag does not maintain a vacuum after
being sealed
• Leaks along the seam may be caused by creases,
crumbs, grease or liquids. Reopen the bag, clean the
upper inside part of the bag and remove any foreign
material from the Sealing Bar before resealing it.
• Check that the bag has no holes in it which have
caused air to leak in. Use paper napkins to protect
any sharp edges on the contents of the bag.
The MAGIC VAC
®
does not create a vacuum in the
containers
• By means of the Connection Hose, connect the con-
tainer lid (or the Cap Attachment if necessary) to the
Air Inlet of the appliance.
• Leave enough room (at least 3 cm) between the con-
tents and the top of the jar or container.
• If liquids come out during the vacuum-packing
process, remember that they must first be chilled in a
refrigerator, not left at room temperature.
• It might be necessary to raise the Vacuum Level (2) to
a higher setting; Turn the Vacuum knob (2) clockwise
to reach the maximum vacuum.
• Check that the rim of the jar or container and the uni-
versal lid are not damaged in the sealing area. Wipe
the rim and cap clean with a cloth moistened with
lukewarm water and repeat the vacuum-packing
process.
• Make sure that the gasket of the container cap or the
universal cap is set properly in place and is not dam-
aged.
Executive containers or MAGIC VAC
MAGIC VAC
®
Universal Caps do not maintain a vacuum
• Make sure that the arrow on the knob of the contain-
er cap is positioned on "VACUUM" before creating a
vacuum in the container and it is positioned on
"CLOSED" after a vacuum is formed.
• Make sure that the O-ring beneath the knob of the
container cap or the universal cap is set properly in
place.
MAGIC VAC
Family containers do not maintain a
®
vacuum
• Make sure that the gasket beneath the central button
(20) of the container cap is set properly in place and
is not damaged.
19
®