To Begin
Product
Description
Product Overview
AC Power
Power Linking

Fuse Replacement

Unpack your Intimidator™ Scan LED 100 and make sure you have received
all parts in good condition. If the box or contents appear damaged, notify the
carrier immediately, not CHAUVET®.
The Intimidator™ Scan LED 100 is a compact LED scanner with sound-
activated programs that dance to the beat of the music with a combined
color/gobo wheel that creates 7 richly saturated projections. Built-in
automatic programs create an easy, synchronized show in Master/Slave
mode and power-linking capability saves time running cables.
Safety Eye
Loop
Microphone
Sensitivity
Adjustment Knob
Microphone
DMX In
DIP Switches
This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
You can link up to 16 Intimidator™ Scan LED 100 products at 120 VAC and
28 units at 230 VAC.
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the safety cap out of the housing.
4. Remove the blown fuse from the clip on the front of the safety cap and
replace with a fuse of the exact same type and rating.
5. Re-insert the fuse holder and reconnect power.