Intimidator™ Scan LED 100 QRG
Mounting
DIP Switches
DMX Linking
Starting Address
Master/Slave
Connection
DMX Values
6-CH
Channel Function
Before mounting this product, read the Safety Notes. The Intimidator Scan
LED 100 can be mounted in any position that provides adequate
ventilation and access with the included mounting bracket and an
appropriate clamp. See the User Manual at www.chauvetlighting.com.
The DIP switches on the rear panel of this product allow for both
standalone and DMX operation. To configure DIP switches for DMX
operation: 1~9 determine the starting address, 10 activates DMX mode.
For standalone operation and more details on DIP switches, consult the
User Manual at www.chauvetlighting.com.
The Intimidator™ Scan LED 100 can work with a DMX controller when
linked by DMX serial connections. Instructions for connecting and
configuring this product for DMX operation are in the User Manual. If you
are not familiar with DMX, download the DMX Primer from
www.chauvetlighting.com.
To ensure full access to all channels in each DMX mode, the highest
recommended DMX address is 507.
The Intimidator™ Scan LED 100 uses the DMX data connection for its
Master/Slave mode. Instructions for connecting and configuring this
product for Master/Slave operation are in the User Manual.
1
Dimmer
2
Strobe
3
Pan
4
Tilt
5
Operating Mode
Gobo Wheel Rotate
6
Speed (use when
CH 5 is 240 249)
Value
Percent/Setting
000 005 Blackout
006 255 1~100%
000 005 Open
006 255 Slow~Fast
000 255 0~180°
000 255 0~90°
000 029 Open (white)
030 059 Gobo 1
060 089 Gobo 2
090 119 Gobo 3
020 149 Gobo 4
150 179 Gobo 5
180 209 Gobo 6
210 239 Gobo 7
240 249 Gobo Wheel Rotate (use CH 6 to control the
speed)
250 255 Sound-Active mode
000 009 Stop
010 255 Slow~Fast
4
EN