Important! The fitting must be installed, flushed
and tested after the valid norms!
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Rate of flow:
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G ½":
Back flow and vacuum breaker
The hot and cold supplies must be of equal
pressures.
To adjust the hot water limiter on single lever
mixers, please see page 7.
No
adjustment
is
continuous flow water heater.
Test certificate
DVGW
10411XXX
10611XXX
Important!
The non return valves must be checked regularly according
to DIN EN 1717 in accordance with national or regional
regulations (at least once a year).
6
max. 1 MPa
0,1-0,5 MPa
1,6 MPa
ca. 17 l/min 0,3 MPa
max. 80°C
150 ± 16 mm
cold right - hot left
necessary
when
using
P-IX
SVGW
PA-IX
9700/ICB
IA-IX
9688/IB
English
Hansgrohe single lever mixers can be used
together
controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa.
Spare parts (see page 3)
1
poignée
screw cover
2
flange
3
nut 97209000
65°C
4
cartridge cpl.
5
flange
6
noise reduction
7
S - unions
8
selector
9
aerator cpl.
10
selector assy
11
non return valve DW 15
XXX = Colors
000 chrome plated
a
810 satinox®
ACS
X
X
with
hydraulically
NF
WRAS
and
thermically
10093XXX
96762000
96763XXX
92730000
97507XXX
96429000
96742000
96297000
96296XXX
96294XXX
94074000
KIWA
X

Publicidad