Installation to Triple Metal Stud Wall
(Metal Stud Accessory Kit ACC 415 and ACC 215 Required
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
Wall plate (AA) can be mounted to three studs that are 16" apart. Use a stud finder to locate the edges of the studs.
1
Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each
stud's center. Place wall plate on wall as a template. The top mounting slots should be located above the desired
screen center as shown in figure 1.3. Note: Screen tilt will determine wall plate location. Level plate, and mark the
center of the six mounting holes. Make sure that the mounting holes are on the stud centerlines. Drill six 1/2" holes
through drywall and metal studs.
Refer to instruction sheet included with Peerless accessory kit ACC 415 and ACC 215 for metal studs to
install togglers.
Loosely fasten mount assembly (AA) to wall using six 1/4-20 x 2-1/2" screws as shown in figure 1.4.
Level, hold, and then tighten all screws.
Note: When mounting equipment weighing greater than 100 lbs, triple stud mounting is strongly recommended. If
mounting to two studs, wall plate may be mounted up to 4" (102 mm) off-center as shown in figure 1.5.
Skip to step 2 of main instruction sheet.
X
CENTER OF
fig. 1.3
SCREEN
Tilt X Distance
0° 9" (229 mm)
2° 6" (152 mm)
5° 9" (229 mm)
10° 6" (152 mm)
fig. 1.5
WARNING
Note: It may be necessary to drill 5/32" pilot holes prior to drilling 1/2" holes.
STUD
AA
PFT660
WALL PLATE
PHILLIPS SCREWS
4"
(102 mm)
2 of 6
)
TOGGLER
1/4-20 X 2-1/2"
AA
PFT660
WALL PLATE
fig. 1.4
ISSUED: 07-11-07 SHEET #: 202-9208MS-1