ESAB Aristo Mig 4002c Instrucciones De Uso página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GB
Check that the unit is connected to the correct mains power supply voltage, and that
it is protected by the correct fuse size. A protective earth connection must be made,
in accordance with regulations.
Recommended fuse sizes and minimum cable areas
50Hz
Mains voltage
Primary current
60% duty cycle
100% duty cycle
Mains cable area (4x)
Fuse anti--surge
60Hz
Mains voltage
Primary current
60% duty cycle
100% duty cycle
Mains cable area (4x)
Fuse anti--surge
* AAG (Arc Air Gouging)
NB: The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
mxx02cwe
Rating plate with supply connection data
Mig 4002c
230/400--415/500 V
56/32(43*)/26 A
43/25/20 A
2
10/4/4 mm
35/25(50*)/20 A
Mig 4002c
230/440--460 V
56/32(43*)/26 A
43/25/20 A
2
10/4/4 mm
35/25(50*)/20 A
- - 10 - -
Mig 5002c
230/400--415/500 V
75/43(50*)/34 A
57/33/26 A
2
16/6/6 mm
63/35(50*)/35 A
Mig 5002c
230/440--460 V
75/43(50*)/34 A
57/33/26 A
2
16/6/6 mm
63/35(50*)/35 A
Mig 6502c
230/400--415/500 V
103/59(65*)/47
80/46/37 A
2
25/10/10 mm
80/50(63*)/50 A
Mig 6502c
230/440--460 V
103/59(65*)/47
80/46/37 A
2
25/10/10 mm
80/50(63*)/50 A

Publicidad

Tabla de contenido
loading

Tabla de contenido