Installation
Instructions
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.monogram.com
If sold outside the U.S. and Canada:
WARNING:
If you wish to use this product with
Liquefied Petroleum (LP) gas containing greater than 10%
butane, you must purchase the butane conversion kit
#WB28T10237. To order, please call 1.888.664.8403
or 1.787.276.4051.
SAFETY INFORMATION
The pressure regulator and burner orifices are set for
natural gas operation.
To convert this cooktop from natural gas operation
to LP operation, the regulator and burner orifices must
be converted. LP burner orifices are attached to the
regulator.
CAUTION
— The cooktop, as shipped from
the factory, is set for use with its intended gas. If you
wish to use your cooktop with the alternate gas, you
must first replace the orifices and convert the pressure
regulator.
WARNING
— This conversion must be
performed by a qualified installer or gas supplier in
accordance with the manufacturer's instructions and
all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result in
serious injury or property damage. The qualified agency
performing this work assumes responsibility for the
conversion.
CAUTION
— The following adjustments must
be made before turning on the burner. Failure to do so
could result in serious injury. Be sure the pressure
regulator has been converted as described in Step 1.
TOOLS YOU WILL NEED FOR
CONVERSION
Crescent wrench
Safety glasses
31-10715
(11-08 JR)
Convert Natural Gas Model ZGU385NSMSS
to LP Gas Operation
7 mm nutdriver
Small flat-head screwdriver
(2 to 2.4 mm or 3/32" tip size,
60 mm long)
1
ADJUST THE REGULATOR
A. Disconnect all electrical power at the main circuit
breaker or fuse box.
B. Shut off the gas supply to the cooktop by closing
the manual shut-off valve.
C. Adjust the pressure regulator by the following
instructions:
• Unscrew the cap.
• Place your thumb against the flat side of the spring
retainer and press down to remove the retainer.
• Carefully look at the spring retainer to locate the NAT
or LP position.
NAT
NAT
NAT. position
Pressure regulator
• Turn the spring retainer over so that the desired gas
is showing on the bottom.
• Snap the retainer back into position.
• Screw the cap back onto the regulator.
2
CHANGE BURNER ORIFICES
INSTALLATION TIP: First remove all
orifices and then start replacing them.
This will help to prevent the possibility
that some may not be replaced.
A. Remove the burner grates,
burner caps and burner heads.
B. Using a 7 mm nut driver, remove
the top burner orifices. There are
two orifices per burner.
The main orifice is
located low in the center
of the burner, while the
simmer orifice is located
higher beside the center
of the burner.
1
Gasket
Cap
LP
Spring
retainer
LP
L.P./propane
position
Burner cap
Burner
head
Burner
Spark igniter
base
Simmer
orifice
Main
orifice

Publicidad

loading

Resumen de contenidos para GE ZGU385NSMSS

  • Página 1 Installation Convert Natural Gas Model ZGU385NSMSS Instructions to LP Gas Operation Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.monogram.com If sold outside the U.S. and Canada: ADJUST THE REGULATOR A. Disconnect all electrical power at the main circuit...
  • Página 2 Installation Instructions for Natural to LP Gas Conversion CHANGE BURNER ORIFICES (cont.) ADJUST BURNER FLAMES IMPORTANT: Orifices must be located exactly as shown. A. Turn all burners on the highest setting and check Carefully read and observe each orifice label for correct the flames.
  • Página 3: Installation Instructions

    Installation Convert LP Gas Model ZGU385LSMSS Instructions to Natural Gas Operation Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.monogram.com If sold outside the U.S. and Canada: ADJUST THE REGULATOR A. Disconnect all electrical power at the main circuit...
  • Página 4 Installation Instructions for LP to Natural Gas Conversion CHANGE BURNER ORIFICES (cont.) ADJUST BURNER FLAMES IMPORTANT: Orifices must be located exactly as shown. A. Turn all burners on highest setting and check the flames. Carefully read and observe each orifice label for correct They should be blue (no yellow tipping) when using location.
  • Página 5: Convertir El Funcionamiento Del Modelo Zgu385Nsmss De Gas Natural A Gas Lp

    Convertir el Funcionamiento del Modelo de Instalación ZGU385NSMSS de Gas Natural a Gas LP ¿Preguntas? Llame al 800.GE.CARES (800.432.2737) o bien Visite nuestra página Web: www.monogram.com Si este producto es para ser usado fuera AJUSTE EL REGULADOR de los EE.UU. o Canadá: A.
  • Página 6 Instrucciones de Instalación para Conversión de Gas Natural a LP CAMBIE LOS ORIFICIOS AJUSTE LAS LLAMAS DEL QUEMADOR DEL QUEMADOR (continuación) A. Encienda todos los quemadores en el ajuste más alto y revise las llamas. Al usar gas LP esta debe estar azul IMPORTANTE: Los ori ficios deben ubicarse exactamente y puede tener la punta de la llama amarilla.
  • Página 7: Convertir El Funcionamiento Del Modelo Zgu384Nsmss De Gas Lp A Gas Natural

    Convertir el Funcionamiento del Modelo de Instalación ZGU384NSMSS de Gas LP a Gas Natural ¿Preguntas? Llame al 800.GE.CARES (800.432.2737) o bien Visite nuestra página Web: www.monogram.com Si este producto es para ser usado fuera AJUSTE EL REGULADOR de los EE.UU. o Canadá: A.
  • Página 8 Instrucciones de Instalación para Conversión de Gas LP a Natural CAMBIE LOS ORIFICIOS AJUSTE LAS LLAMAS DEL QUEMADOR DEL QUEMADOR (continuación) A. Encienda todos los quemadores en el ajuste más alto y revise las llamas. Al usar gas natural esta debe estar IMPORTANTE: Los orifi cios deben ubicarse exactamente azul (sin puntas amarillas).