Installation Instructions for Natural to LP Gas Conversion
2
CHANGE BURNER ORIFICES (cont.)
IMPORTANT: Orifices must be located exactly as shown.
Carefully read and observe each orifice label for correct
location.
SIMMER
ORIFICES
MAIN
ORIFICES
C. Install the proper orifices in the exact locations as noted
in the illustrations above.
D. Return the natural gas orifices to the bracket and
reattach the bracket and the instruction sheet to the
pressure regulator using the screw removed previously.
E. Replace the burner bases, heads, caps and top grates.
The 34SL and 51SN
are for all five
burners.
2
3
ADJUST BURNER FLAMES
A. Turn all burners on the highest setting and check
the flames. They should be blue in color and may have
some yellow tipping at the ends of the flame when using
LP gas. Foreign particles in the gas line may cause
an orange flame at first, but this will soon disappear.
B. Turn the cooktop burner knob to "LO" while observing
the flame.
Adjust the setting of the upper row of flames using
the valve bypass screw as follows:
Adjustments must be made with two other burners in
operation on a medium setting. This prevents the upper row
of flames from being set too low, resulting in the flame
being extinguished when other burners are turned on.
C. To adjust the flame, remove the knobs. Insert a
screwdriver through the access hole in valve shaft
as shown.
• If the flames were too small or fluttered, open the valve
more than the original setting.
• If the flames blew away from the burner, close the valve
more than the original setting.
D. Make the adjustment by slowly turning the screw until
flame appearance is correct.
E. Testing Flame Stability:
Test 1 – Turn the knob from "HI" to "LO" quickly.
If the upper row of flames goes out at this setting,
increase the flame size and test again.
Test 2 – With the burner on "LO", open and close the
cabinet door under the cooktop. If the flame is
extinguished by the air currents created by the
door movement, increase the flame height and
test again.
NOTE: When the burner is on the "SIM" setting, the upper
row of flames will go out.
F. Flame Recheck:
After the adjustment is made, turn all burners off. Ignite
each burner individually. Observe the flame at the "HI"
position. Rotate the knob to the lowest setting and be
sure that the flame size decreases as the knob is
rotated counterclockwise.
Once the conversion is complete and checked ok,
fill out the conversion sticker and include your name,
organization and the date the conversion was made.
Apply the sticker near the cooktop gas inlet opening
to alert others in the future that this appliance has been
converted. If converting back to the original gas, please
remove the sticker so others know the appliance is set
to use its original gas.