POWER SAVE
scan rate max, standby disabled, sleep disabled
READING PARAMETERS
hardware trigger, trigger active level, no trigger timeout,
Flash On = 1 sec, Flash Off = .6 sec, one read per cycle,
safety time .5 sec, beeper intensity high, tone 2, beeper type
monotone, beeper length short
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit
control enabled, Puzzle Solver disabled, decoding safety
= one read
CODE SELECTION
enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
Interleaved 2/5
check digit control and transmission, variable length
code; 4-99 characters
Standard Code 39
no check digit control, variable length code; 1-99
characters
Code 128
variable length code; 1-99 characters
disabled codes
EAN
pharmaceutical codes, MSI, Plessey, Telepen, Delta
IBM, Code 11, Code 16K, Code 49, RSS Codes
ADVANCED FORMATTING PARAMETERS
concatenation disabled, no advanced formats defined
128,
ISBT128,
Code
93,
Codabar,